- ページ 3

ドライヤー Bosch WTA35 SeriesのPDF 修理指示をオンラインで閲覧またはダウンロードできます。Bosch WTA35 Series 15 ページ。 Electric vented dryer, electric condensation dryer
Bosch WTA35 Series にも: 使用説明書 (44 ページ), 取扱説明書 (24 ページ)

Bosch WTA35 Series 修理指示
TUMBLE DRYER
Operating and display module is situated in the fascia.
Control and power module is situated on the right frame support.
Thermistor sensor for measuring the air temperature.
Condensation pump is situated in the base group underneath the belt tensioning device.
Motor is situated on the right in the base group.
Heater on the rear panel – under the heating duct cover.
Bimetallic thermal cut-out (>170 C) is situated directly on the heater.
1.1
Operating and display module
The operating and display module is used to input and output information. It houses all the
direct input buttons, all signalling elements, e.g. LEDs, selector switches and signal
transmitters. Models are encoded by breaking off the side bridges.
1.2
Control and power module
The module houses all the significant components, e.g. micro-controller, relays, power
supply, etc. It performs complex functions with respect to controlling drying sequences,
monitoring the temperature, ascertaining parameters and actuating the operating and
display section. The appliance is switched over from 16 A to 10 A by means of a wire jumper.
Wire jumper closed 16 A – Wire jumper open 10 A. Control and power module
(software version is indicated on the processor) changes automatically from 16 A to 10 A.
1.3
Thermistor sensor for measuring the air temperature
Thermistor sensors measure the temperature of the process air at three different points in
the appliance (NTC thermistor – NTC stands for Negative Temperature Coefficient).
NTC R3
is situated in the ring insert under the door and measures the exhaust-air temperature.
NTC R4
is situated in the air current in front of the heater.
r120085e -15/3
04.99
mask V 4.00