- ページ 16
エアコン ANDI MPK1-14ER-QB6のPDF サービスマニュアルをオンラインで閲覧またはダウンロードできます。ANDI MPK1-14ER-QB6 20 ページ。 Room air conditioner
Andi-Co Australia Pty Ltd
the display board.
4.5 To replace the Main Control board.
Remove the screws fixing the enclosure cover.
Take care of the wiring diagram on the cover. The
wiring diagram is important for reference when
wiring.
Pay attention to the wires in the enclosure.
Service manual for K1 portable Series
1
2
3
4
1: Terminate to display board
2: Terminate to condenser fan motor
3: Out-put of transformer
4: Terminate to evaporator fan motor
5: Terminate to compressor
6: Terminates (N) to condenser fan motor, electric
heater, pump, power cord, compressor
capacitor
7: Terminate to electric heater
8: Terminate (L) to power cord
9: Terminate (L) to pump
10: Terminate to input of transformer
Take care to the grounding wires if need to
disconnect.
15
5
6
7
8
9
10