INSTALLATION AND OPERATION MANUAL
Installation Instructions
Figure 4 – DIP Switches
DIP Switches on RLMCSFP24DC,
RLMCSFP48DC, and RLMCSFPPOEHO
Models
Table 2 – DIP Switch Settings
SW NAME
1
Link Fault Enable Port 1 Link Fault Pass-Through Disabled
2
3
FFE
4
PS Fault Enable
5
6
1000/100 (SFP Speed)
1 - SET DATA RATE DIP SWITCHES
Locate the 100/1000 data rate DIP switch on the bottom panel of the unit.
Set the data rate according to bandwidth required.
NOTE: If two units are connected via the SFP Port, the data rate must be set the same on both units, and must match the
data rate of the installed SFPs. Data rate settings are read on start-up, so restart the unit after making any changes.
2 - SET FAULT DIP SWITCHES
Locate the LFE, FFE, and PSE DIP switches on the bottom panel of the unit.
LFE1: If the Copper Port is Down or Not Connected, the Optical Port will turn on and off at a ~1 sec rate to indicate copper port
fault and the alarm relay will be triggered.
FFE: If the optical link is lost or there is a power failure then the alarm relay output will be triggered.
NOTE: You may select multiple fault event triggers.
NOTE: Power Supply Fault DIP Switch is only available on Redundant Power Models. When a redundant power supply is
available, a failure of power on one power supply will trigger the alarm relay output.
NOTE: Restart not required when making changes to this DIP switch setting.
3 - CONNECT GROUND WIRING
Connect Ground Wiring to ground screw and tighten nut to secure.
4 - CONNECT FAULT RELAY WIRING
Connect Fauly Relay device to 3-pin terminal block. The COM to N/C will be shorted in the fault condition.
5 - CONNECT DATA WIRING
Connect RJ-45 Ports to field wiring using Cat5/5e/6 cable.
6 - CONNECT NETWORK WIRING
Using fiber optic cabling appropriate to the installed SFP, connect the unit to a network device.
TECH SUPPORT: 1.888.678.9427
DIP Switches on RLMCSFPHV Model
OFF (DOWN)
N/A
Fiber Fault Relay Disabled
Power Supply Fault Relay Disabled
N/A
100 Mbps Speed Set Speed must match speed of installed
SFP. Reset power if switch or SFP is changed.
(UTP MODELS ONLY, FOR COAX MODELS SKIP TO STEP 3)
ON (UP)
Link Fault Pass-Through Enabled
N/A
Fiber Fault Relay Enabled
Power Supply Fault Relay Enabled
N/A
1000 Mbps Speed Set. Speed must match speed of
installed SFP. Reset power if switch or SFP is changed.
RLMCSFP SERIES
INS_RLMCSFP_REV–
Rev. 18 Sep 2020 PAGE 4