- ページ 7
エクステンダー Comnet FDW1000M/RのPDF 設置および操作マニュアルをオンラインで閲覧またはダウンロードできます。Comnet FDW1000M/R 12 ページ。 Optical wiegand, magstripe & f/2f data extender
INSTALLATION AND OPERATION MANUAL
FIGURE 12 – SUPERVISED CONTACTS
The system provides a supervised signal to the panel interface by reading the supervised status of the contacts
connected to the FW1000/R unit.
CENTRAL
2K
1K
REMOTE
Door
1K
N.C.
Rex
N.O.
1K
TECH SUPPORT: 1.888.678.9427
1 8 – 16VDC
1 8 – 16VDC
2 GND
2 GND
FDW1000 S
M
CENTRAL
STATUS LED
STATUS LED
DATA
EXTENDER
1 EXP(+)
1 EXP(+)
2 EXP(–)
2 EXP(–)
3 +5V OUT
3 +5V OUT
4 PROG RES 2
4 PROG RES 2
5 PROG RES 1
5 PROG RES 1
6 LED IN
6 LED IN
7 D1/DOUT
7 D1/DOUT
8 D0/COUT
8 D0/COUT
1 8 – 16VDC
1 8 – 16VDC
2 GND
2 GND
FDW1000 S
M
REMOTE
STATUS LED
STATUS LED
DATA
EXTENDER
1 EXP(+)
1 EXP(+)
1K
2 EXP(–)
2 EXP(–)
3 +5V OUT
3 +5V OUT
1K
4 RLY 4 IN
4 RLY 4 IN
5 RLY 3 IN
5 RLY 3 IN
6 LED OUT
6 LED OUT
7 D1/DIN
7 D1/DIN
8 D0/CIN
8 D0/CIN
1 8 – 16VDC
1 8 – 16VDC
2 GND
2 GND
RLY 4 N.O. 1
RLY 4 N.O. 1
FDW1000 S
/C
M
/C
FDW1000 S
M
RLY 4 N.O. 1
FDW1000 S
M
/C
RLY 4 COM 2
RLY 4 COM 2
CENTRAL
RLY 4 COM 2
CENTRAL
CENTRAL
RLY 4 N.C. 3
RLY 4 N.C. 3
STATUS LED
DATA
RLY 4 N.C. 3
DATA
STATUS LED
DATA
RLY 3 N.O. 4
RLY 3 N.O. 4
RLY 3 N.O. 4
EXTENDER
EXTENDER
EXTENDER
RLY 3 COM 5
1 EXP(+)
RLY 3 COM 5
1 EXP(+)
RLY 3 COM 5
RLY 3 N.C. 6
2 EXP(–)
RLY 3 N.C. 6
2 EXP(–)
RLY 3 N.C. 6
GND 7
GND 7
3 +5V OUT
GND 7
3 +5V OUT
AUX OUT 8
AUX OUT 8
4 PROG RES 2
AUX OUT 8
4 PROG RES 2
RLY 2 IN 9
RLY 2 IN 9
5 PROG RES 1
RLY 2 IN 9
5 PROG RES 1
RLY 1 IN 10
RLY 1 IN 10
6 LED IN
RLY 1 IN 10
6 LED IN
7 D1/DOUT
7 D1/DOUT
8 D0/COUT
8 D0/COUT
1 8 – 16VDC
1 8 – 16VDC
2 GND
2 GND
RLY 2 N.O. 1
FDW1000 S
RLY 2 N.O. 1
M
/R
RLY 2 N.O. 1
/R
FDW1000 S
M
/R
FDW1000 S
M
/R
RLY 2 COM 2
RLY 2 COM 2
REMOTE
RLY 2 COM 2
REMOTE
REMOTE
RLY 2 N.C. 3
RLY 2 N.C. 3
STATUS LED
STATUS LED
RLY 2 N.C. 3
DATA
DATA
DATA
RLY 1 N.O. 4
RLY 1 N.O. 4
RLY 1 N.O. 4
EXTENDER
EXTENDER
EXTENDER
RLY 1 COM 5
RLY 1 COM 5
1 EXP(+)
1 EXP(+)
RLY 1 COM 5
RLY 1 N.C. 6
2 EXP(–)
RLY 1 N.C. 6
2 EXP(–)
RLY 1 N.C. 6
GND 7
GND 7
3 +5V OUT
GND 7
3 +5V OUT
AUX IN 8
AUX IN 8
4 RLY 4 IN
AUX IN 8
4 RLY 4 IN
9
9
5 RLY 3 IN
9
5 RLY 3 IN
10
6 LED OUT
10
10
6 LED OUT
7 D1/DIN
7 D1/DIN
8 D0/CIN
8 D0/CIN
FDW1000(M,S)
1K
RLY 4 N.O. 1
/C
RLY 4 COM 2
RLY 4 N.C. 3
RLY 3 N.O. 4
RLY 3 COM 5
RLY 3 N.C. 6
1K
GND 7
AUX OUT 8
RLY 2 IN 9
RLY 1 IN 10
RLY 2 N.O. 1
RLY 2 COM 2
RLY 2 N.C. 3
RLY 1 N.O. 4
RLY 1 COM 5
RLY 1 N.C. 6
GND 7
AUX IN 8
9
10
INS_FDW1000_EXP100_REV– 04/25/12 PAGE 7
I1–
I1+
I2–
I2+