- ページ 12

ホブ Electrolux EGC3322NOKのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Electrolux EGC3322NOK 16 ページ。 For a modern, premium look, choose this gas on glass hob. it combines the precision of cooking with gas, with the smooth style of ceramic glass.
Electrolux EGC3322NOK にも: ユーザーマニュアル (16 ページ)

Electrolux EGC3322NOK ユーザーマニュアル
12
www.electrolux.com
come in touch with mobile parts or they
are not squeezed. Also be careful when
the hob is put together with an oven.
Make sure that the gas
supply pressure of the
appliance obeys the
recommended values.
If the supplied pressure has not the
specified value, it is necessary to
assemble a proper pressure regulator in
compliance with the standard UNI EN 88.
For Liquid Gas (LPG) the use of pressure
regulator is allowed only if they are in
compliance with UNI EN 12864. The
adjustable connection is fixed to the
comprehensive ramp by means of a
threaded nut G 1/2". Screw the parts
without force, adjust the connection in the
necessary direction and tighten
everything.
A) End of shaft with nut
B) Washer
C) Elbow (if needed)
Rigid connection:
Carry out connection by using metal rigid
pipes (copper with mechanical end) (UNI-
CIG 7129).
Flexible connection:
Use a flexible pipe in stainless steel (UNI-
CIG 9891) with a maximum length 2 m.
WARNING!
When installation is complete,
make sure that the seal of
each pipe fitting is correct.
Use a soapy solution, not a
flame!
8.3 Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. With a socket spanner 7 remove the
4. Assemble the parts, follow the same
5. Replace the rating plate (it is near the
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure
adjuster on the gas supply pipe.
8.4 Adjustment of minimum level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
A
3. Remove the knob.
4. With a thin screwdriver, adjust the
B
C
5. If you change:
8.5 Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate agree
injectors and replace them with the
ones which are necessary for the type
of gas you use (see table in "Technical
Information" chapter).
procedure backwards.
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied with
the appliance.
position.
bypass screw position (A).
A
• from natural gas G20 20 mbar to
liquid gas, fully tighten the bypass
screw in.
• from liquid gas to natural gas G20
20 mbar, undo the bypass screw
approximately 1/4 of a turn.
WARNING!
Make sure the flame does not
go out when you quickly turn
the knob from the maximum
position to the minimum
position.