ヒーター Atlantic F129 Design CMG-BD 1のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Atlantic F129 Design CMG-BD 1 17 ページ。 Electrical convector
MODEL SPECIFICATIONS
Specification
Rated heat output
Minimum heat output
Long-term maximum heat output
At the maximum heat output
At the minimum heat output
In stand-by mode
Specification
Electronic room temperature control and weekly
programmer
Room temperature control with user presence
sensor
Room temperature control with open window
sensor
Remote control option
Adaptive activation control
Activation duration limit
Black globe sensor
MAINTENANCE
ATTENTION! All operations are performed only with the device
completely de-energized!
-
In order to maintain the performance of the appliance, you should
use a vacuum cleaner or brush twice a year to remove the dust from the
upper and lower grids. Every five years, a maintenance engineer should
check the inside of the appliance.
-
In a polluted atmosphere, dirty marks could appear on the
appliance's grille. This is because of the poor quality of the ambient air. In
this case, it is advisable to check that the room is properly ventilated (fan,
air intake, etc.) and that the air is clean. Such dirty marks are no reason to
have the appliance replaced under the terms of the warranty. The casing
of the appliance can be cleaned with a damp cloth, do not use abrasive
products.
Auxiliary power consumption
Type of heat output/room temperature control
Other control options
CMG-BD1
Heat output
14
Symbol
Value
P nom
0.5 - 2.5
P min
0.0
P max, c
2.5.
el max
0.000
el min
0.000
0.29
el sb
0.000
Additional
Unit
information
Yes
No
No
No
Yes
No
No
Unit
kW
kW
kW
kW
kW
W
kW