- ページ 2

ケーブルとコネクター Andrew HELIAX HJ11-50のPDF インストレーション・インストラクションをオンラインで閲覧またはダウンロードできます。Andrew HELIAX HJ11-50 4 ページ。 Coaxial cable

3
Remove burrs
4
Remove part
of insulator
5
Slide clamping ring onto cable
6
Remove all
copper particles
Apply silicone grease to
gasket threads and screw
gasket against jacket
7
Screw helix ring onto
outer conductor and
against gasket. Slots
must be at cable end.
1/4" (6.3 mm)
9
Tap outer conductor against
inner edge of helix ring
Tap outer conductor
against end of helix
ring and bend tabs
into slots in ring
8
Cut slits in outer conductor
at 3/16" (5 mm) intervals