12. Functions sequences
Imbalance during extraction
In the event of imbalance, extraction is halted so that the load can be manually
6
redistributed.
The sensor arm of the microswitch (SW3) is activated if there is load imbalance, and it
in turn sends a signal to the circuit board (S2:2) for activation of the braking function and
subsequent possibility of lid opening function.
12.10
487 03 29 91