- ページ 9
水ポンプ Dresser iCIP 200 SeriesのPDF インストレーション&オペレーション手順書をオンラインで閲覧またはダウンロードできます。Dresser iCIP 200 Series 14 ページ。 Intelligent chemical injection pump
panels, a microprocessor measures and determines the
optimum operating charging point to charge the battery. A
low voltage disconnect is included in the design to protect
the battery from excessive discharge. Two LED's provide
a visual indication as to the status of the controller. A
temperature sensor is also provided to monitor battery
temperature; this sensor provides feedback to the solar
converter and will adjust battery charge conditions
accordingly as the temperature changes.
Gel Cell Battery
All batteries conform to BCI specifications. Batteries are
maintenance free. Sealed construction eliminates: periodic
watering, corrosive spills and fumes. Electrolyte will not
stratify, no equalization charging required. Allows for faster
recharging intervals. Battery operating temperatures range
from -76°F (-60°C) to 140°F (60°C). All Batteries in
multi-battery configurations are to be wired in Parallel
(connecting Positive to Positive and Negative to Negative).
All batteries cables are equipped with a current limiting
devise to protect against an over current condition.
Simplex Pump
All pump heads have a standard 316 Stainless Steel body
and incorporate the Texsteam proven plunger and packing
design technology. Pump outputs are a basic setup input
feature. The Daily Volume input requirement and the head
size are all that is needed, simply Set It and Forget It. Daily
Volumes can be entered in either SI (System International)
Liters/Day or US customary units in Quarts/Day. Output
volumes remain constant as pressure requirements change.
Min/Max daily volumes based on continuous duty range
from 1.75 to 103 quarts/day (1.66 to 97.47 Liters). Output
pressures are achievable for the 3/16 and 1/4 in. pump head
models up to 5,000 psi.
Electric Motor
DC electric motors have gone through rigorous testing prior
to distribution to market. The motors are designed for: high
efficiency, low power consumption, long life, continuous
duty cycle and maintenance free.
Head Available in
3/16", 1/4", 3/8",
and 1/2"
Motor Cover
Mounting Base
Figure 17 – Pump and Electric DC
Motor Assembly
Plunger Packing Kit
Packing Nut
Plunger
Locking Nut
Figure 18 – Chemical Injection Pump Head
Elimination of Pump Drag and Friction
Packing Tightness
Particular attention should be given to Packing Nut tightness.
Over tightening of Packing Nut can result in excessive loses
of electrical power, which effects battery life, and pre-mature
seal packing degrading. The method for tightening all
Texsteam pumps is the same. NEVER ADJUST PACKING
WITH THE PUMP RUNNING. Loosen the packing gland nut
until you can feel that it is free, then retighten until you feel a
snug fit, then one more little tightening, the size of one
(only) notch in the packing gland nut. If this does not work,
stop the pump and tighten only one more notch.
9
TEXSTEAM
field proven
Pump
DC Motor
O-Ring Seal
Priming Valve
O-Ring Seal