Quick Set Pump Starting Parameters
1. Toggle down through the menu tree (Reference Figure
14) using the joystick control (Reference figure 13). Go
to "SETUP/UNITS" and pick the units of measure US
(Quarts/Day) or SI (Liters/Day). Press down on the
joystick, "DONE" should be displayed.
2. Next go to "SETUP/HEAD SIZE" or Pump Head Size.
This will automatically set the pump displacement with
regards to the cam and plunger diameter. Select on of
the following head sizes: 3/16, 1/4, or 3/8 depending on
the size delivered.
Head Size
Low
3/16"
3
3
1/4"
3
3
3/8"
5
5
1/2"
5
5
Table 1 – Head Size vs. Volume Range
Motor Controller and
Configuration Firmware
The motor Controller has been designed to provide four
different configuration packages. Features include: A variable
speed motor that will match pump output requirements; a
4-digit LED (Light Emitting Diode) front panel mount display;
Manual field input capabilities using a 5 position entry
joystick device and CSA approved Motor Controller.
Reference Figure 13.
•
The Basic "Solar Solutions Series 100" will incorporate
the programmable pumping input parameters.
Configurations files can be downloaded with the aid of a
laptop PC. These configurations files are easily saved
and stored in an Excel or XLS format. Reference the
User Terminal Handbook for full use of the
communication software.
RPM Range
Volume Range
High
Low
45
1.75
45
1.66
45
3.07
45
2.91
45
11.52
45
10.90
45
20.48
45
19.38
Press down on the joystick, "DONE" should be
displayed Select the head size based on the volume
requirements based on Table 1.
3.
Lastly go to "SETUP/DAILY VOLUME" and hold down
the Joystick either up or down to increase or decrease
the daily volume. Press down on the joystick, "DONE"
should be displayed. Daily volume is dependant on the
units of measure selected above in Step 1 and head size.
4.
Toggle up to "OPERATION", move the joystick to the
right and select "RUN", press down on joystick,
"DOWN" should be displayed, and the iCIP should now
be operating and pumping.
Units of
High
Measur
26.31
Quarts/Day
24.87
Liters/Day
46.07
Quarts/Day
43.61
Liters/Day
103.68
Quarts/Day
98.12
Liters/Day
184.29
Quarts/Day
174.43
Liters/Day
PC Data Logging &
Communication Module
Connection
LED
Display
Joystick Selector
Figure 13
6
Pressure Range
Standard
High Pressure
0 – 5000 PSI
0 – 5000 PSI
0 – 5000 PSI
0 – 5000 PSI
0 – 1500 PSI
1500 – 3000 PSI
0 – 1500 PSI
1500 – 3000 PSI
0 – 1000 PSI
1000 – 2000 PSI
0 – 1000 PSI
1000 – 2000 PSI
Termination
RS232/485
PC Interface
Connection