- ページ 5

換気フード Electrolux E36WV60PPSのPDF 設置・使用・お手入れマニュアルをオンラインで閲覧またはダウンロードできます。Electrolux E36WV60PPS 12 ページ。 30"(76.2 cm) and 36"(91.4 cm) range hood
Electrolux E36WV60PPS にも: 設置・使用・お手入れマニュアル (12 ページ)

List of materials- Electrical & Installation
re uirements
CAUTION!
Remove carton carefully. Wear gloves to protect
against sharp edges.
Parts supplied with unit for the installation
°
Hood canopy assembly with blower.
°
Lamp already installed.
°
Transition (31A '' x 10" rectangular)
°
Grease filter.
°
Hardware bag with:
°
Useand Care/Installation
Manual
°
3- 4x8 screws (to assemble Transition)
°
6- 4,5x13 screws
4- 10x50 screws
°
Torx 20 Adapter
Remove the protective film covering the product be-
fore putting into operation.
Tools/Materials required
Wire nuts
Metal duct length to suit installation
1A"Romex wire connector
Measuring tape
Pliers
Gloves
Knife
°
Safety glasses
Electric drill with _6" and 3/s"Bits
Spirit level
°
Duct tape
°
Screwdrivers:
Phillips (Posidrive) #2
°
Torx # 2
°
Wire cutter/stripper
°
Masking tape
Hammer
Saw, jigsaw or reciprocating saw
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and
in conformance with National Electrical Code, ANSI/
NFPA 70 (latest edition), or CSA Standards C22.1 -
94, Canadian Electrical Code, Part 1 and C22.2 No.
0-M91 (latest edition) and all local codes and ordi-
nances.
If codes permit and a separate ground wire is used, it
is recommended that a qualified electrician determine
that the ground path is adequate.
A copy of the above code standards can be obtained
from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused
electrical circuit is required.
If the house has aluminum wiring, followthe
procedure below:
1. Connect a section of solid copper wire to the
pigtail leads.
2. Connect the aluminum wiring to the added
section of copper wire using special co
nectors and/or tools designed and UL listed
for joining copper to aluminum.
Follow the electrical connector manufacturer's recom-
mended procedure. Aluminum/copper connection
must conform with local codes and industry accepted
wiring practices.
°
Wire sizes and connections must conform with
the rating of the appliance as specified on the
model/serial rating plate.
The model/serial plate is located behind the filter
on the top wall by the electrical box.
°
Wire sizes must conform to the requirements of
the National Electrical Code, ANSI/NFPA 70 (la
est edition), or CSA Standards C22. 1-94,
Canadian Electrical Code, Part 1 and C22.2
No. 0-M91 (latest edition) and all local codes and
ordinances.