Cold water piping should be provided with a 350 – 500 kPa Pressure
Limiting Valve at the point of cold water connection to the water heater.
In addition to the Pressure Limiting Valve, it is a requirement of AS 3500.4
& NZBC G12 that both a Stop Valve and a Non Return Valve are installed
upstream of the Product.
 
No parts (stop valve, pressure reducer, etc.) must be placed between the
pressure limiting valve and the cold water inlet of the water heater, apart
from a copper pipe.
 
Note: since limited water discharge from pressure limiting valve is normal in
the heating operation, the discharge pipe needs be connected to external
drain.
Commissioning
Never switch the water heater on without it being filled with water.
Before switching on, open the hot water taps, bleed the pipes until no air is
present and fill the appliance.
Check that the pipes and the door seal under the cover are not leaking. If
there are any leaks tighten gently. Check that the water safety devices
are working and fill the appliance. Switch on the appliance. After 5 to
20 minutes according to the capacity of the appliance, water should
start dripping from the drain outlet. This is normal and results from the
10