- ページ 8
換気フード Electrolux EFC 639.1のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Electrolux EFC 639.1 14 ページ。 Electrolux cooker hood
Technic Details
Model
Dimensions
height
width
depth
Lighting
Grease filter
max absorbed power
We reserve the right to generate constructive and chromatic modifications as required by technological
growth.
Special accessories
Carbon filter
Installation
Unpacking
Check that the cooker hood has no damages.
Transportation damages should immediately be
reported to the one responsible for the transport
Damages, faults and eventually missing details
should immediately be reported to the seller.
Take care of the packing material so that small
children cannot play with it.
Placement
The hood is to be mounted on the wall.
When installed, the hood must be not less than
60 cm. above electric burners or 75 cm. above
gas or mixed-fuel burners (fig. 7).
Electrical connection
The hood has a power cord with moulded plug
with earth connection to be connected to a wall
outlet of 230 V.
The power outlet should be pre-mounted in
such a way that the power cord is invisible
when the hood is fully mounted.
The power cord length is 1,25 m.
Safety warnings for the electrician
Before connecting the appliance to the power
supply, check that the voltage indicated on the
rating plate corresponds to the mains power
supply available. Appliances fitted with a plug
can be connected to any standard power socket
within easy access.
Should it be necessary to provide a fixed con-
nection, the hood must only be installed by an
electrician authorised by the local electricity
EFC 009.1
752-930 mm
1000 mm
700 mm
4 x 20 W
2
240 W
942 120 182
Fig. 7
board. When installing, an omnipolar
disconnector with a distance of at least 3 mm
between contacts must be provided.
This disconnector may be for example a switch,
fuses (plug fuses must be removed from the
fuse box, fault current switches and remote
switches with a distance of over 3 mm between
contacts.
The manufacture declines all responsibility for
malfunctions resulting from failure to comply
with the above instructions.
If the power socket is applied directly above the
hood this gives two advantages:
1. the socket is not visible.
2. the appliance can be disconnected at need
merely be removing the plug.
Electrical connection
220-240 V – by means of fixed power cable
with plug.
(Fixed connection of the appliance must only be
carried out by an authorised electrician.)
38
Min
Min
75cm