Warranty Claims

• In case of warranty claims, pump should be returned to place of purchase accompanied
by original receipt.
Cleaning
Mag Drive pumps will require periodic cleaning of the magnetic rotor and rotor chamber.
Please follow the directions below for proper cleaning procedures:
• Unthread the pre-filter by turning it in a counter clockwise direction.
• Remove volute by rotating it in a counterclockwise half turn while pulling lightly outward
from the pump body.
• Remove the impeller assembly from the rotor chamber.
Note: The impeller assembly is comprised of six individual parts shown in the image below.
Take care not to lose or misplace any of these pieces during the cleaning process.
Pre-filter
• Inspect the magnetic rotor and the rotor chamber for built up debris. Loose debris can be
flushed out with clean water. Often in hard water, well water or pond-free applications,
debris may appear as a crusty film around the rotor and in the rotor chamber. Remove
this film using a scrub brush and white vinegar.
• Inspect the intake O-ring for nicks or breaks.
• Re-assemble the impeller assembly insert it into the rotor chamber.
• Attach the volute by applying pressure and rotating it in a clockwise half turn.
• Replace the pre-filter.
Volute
Pre-filter
Ceramic Shaft
Intake
O-ring
(see larger image below)
Rubber Bushing
Impeller/
Magnetic Rotor
Friction Washer
Rotor
Chamber
Pump Body/Motor
Impeller
Assembly
Pump Base