- ページ 10

除湿機 Dri-Eaz DRIZAIR 120のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Dri-Eaz DRIZAIR 120 11 ページ。 Refrigerant dehumidifier

DRIZAIR 120 REFRIGERANT DEHUMIDIFIER TROUBLESHOOTING
Troubleshooting solutions fall into two categories listed in the third column. Field Solutions (FS) are those proce-
dures that can be handled by the technician in the field. Others solutions should be handled by a repair technician and
are listed as Authorized Service Technician (AST).
WARNING: All the service procedures below should be executed with power off i.e. unplugged.
PROBLEM
The dehumidifier does not op-
erate
The compressor will not start
Fan blade not turning
Dehumidifier operating but
room not dry
Only partial frost or moisture
on coils
No moisture or frost on coils
COPYRIGHT  DRI-EAZ PRODUCTS, INC. 1996
1. No power to machine
2. Switch not turned on
1. Unit turned on too soon
2. Faulty or broken wire
3. Overload preventing com-
pressor start up
4. Bad compressor
5. Defective relay
1. Obstructed or bent fan
blade
2. Loose fan blade nut
3. Loose or broken wire
4. Burned out fan motor
1. Not enough time to get
dry
2. Poor air movement
3. Excessive air infiltration
1. Possible leak in system
2. Low charge in system
1. Possible leak in system
2. Capillary tubing damaged
3. Compressor not running
FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIBUTOR,
OR THE DRI-EAZ SERVICE DEPARTMENT AT (360) 757-7776
Caution
CAUSE
FS
FS
FS
FS
AST
FS
AST
AST
AST
FS
AST
AST
FS
FS
FS
AST
AST
FS
AST
AST
FS
10
SOLUTION
1. Plug in the unit
2. Check power at outlet
3. Turn on the switch
1. Switch off unit and wait 5 mi-
nutes before starting
2. Replace or repair broken/loose
wire
3. Reduce room temperature be-
low 100° F (38° C)
4. Replace or repair compressor
5. Use Volt/amp meter to check
relay
1. Remove obstruction or replace
fan blade.
2. Tighten fan blade nut
3. Replace broken wire
4. Replace fan motor
1. Allow more time for drying
2. Increase air movement with
Dri-Eaz TurboDryers
3. Reduce airflow into the area
being dried
1. Check for leak with gas leak
detector
2. Repair and recharge system
3. Contact distributor or Dri-Eaz
Products
1. Check for leak with gas leak
detector
2. Look for damage, replace tub-
ing
3. See Compressor Section