- ページ 4

浄水器 Atlantic Ultraviolet 10-0508BのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Atlantic Ultraviolet 10-0508B 20 ページ。 Germicidal ultraviolet water purifiers
Atlantic Ultraviolet 10-0508B にも: オーナーズマニュアル (16 ページ)

PRODUCT APPLICATION

C
ONSTRUCTION
The water purifier is designed to mount horizontally.
The water purifier's chamber is passivated and electropolished type 304 Stainless Steel.
TM
EASY-OFF
end caps allow for quick and easy lamp change, without disconnecting from the water supply or draining the
purifier. No tools are required.
P
O
RINCIPLE OF
PERATION
®
The MINIPURE
design has been carefully conceived to provide adequate germicidal dosage throughout the disinfection chamber.
The dosage, as it applies to ultraviolet disinfection, is a function of time and the intensity of ultraviolet radiation to which the water is
exposed. The exposure time, in seconds, is the total time it takes the water to flow through the disinfection chamber exposing it to the
germicidal lamp. Exposure time is related to the flow rate; the higher the flow rate, the lower the exposure time or the lower the flow
rate, the higher the exposure time. The ultraviolet intensity is the amount of energy, per unit time, emitted by the germicidal lamp. The
dosage is the product of ultraviolet intensity and the exposure time. The operation of the MINIPURE
Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall.
Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp.
The LED indicator light, located on the ballast, provides visual indication of germicidal lamp operation.
Water leaving the purifier is instantly ready for use, no further contact time is required.
L
U
IMITATION OF
SE
The water purifier is intended for the use with visually clear water, not colored, cloudy or turbid. See "Water Quality" section below.
The water purifier is NOT intended for the treatment of water that has an obvious contamination or intentional source, such as raw
sewage; nor is the unit intended to convert wastewater to microbiologically safe drinking water.
W
Q
ATER
UALITY
Water quality plays a major role in the transmission of germicidal ultraviolet rays. It is recommended that the water does not exceed
the following maximum concentration levels:
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures
to improve water quality to treatable levels. If, for any reason, it is believed the ultraviolet transmission is not satisfactory,
contact the factory.
4
Table 1 - Maximum Concentration Levels
Turbidity
Manganese
Total Suspended Solids
pH:
Color:
Hardness
Iron
Tannins:
UV Transmission
* Contact Factory for recommendations on applications where UV transmission is < 85%
< 1 NTU
0.05 mg/1
10 mg /1
6.5 - 9.5
None
6 GPG or 102.6 PPM
0.3 mg/1
< 0.1 ppm (0.1 mg/l)
>85% per cm*
®
is as follows: