- ページ 10
浄水器 Atlantic Ultraviolet MIN-1のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Atlantic Ultraviolet MIN-1 16 ページ。 Ultraviolet water purifiers
Atlantic Ultraviolet MIN-1 にも: オーナーズマニュアル (16 ページ)
L
I
AMP
NSTALLATION OR
120
50/60H
V
Z USING BALLAST NO
Step 2 - Remove End-Cap
SAFETY EQUIPMENT REQUIRED TO PERFORM TASK
1.
WARNING: Disconnect power to water purifier, and remove ground connector from the chamber.
2.
Remove EASY-OFF
3.
Pull lamp cord and carefully withdraw lamp approximately 2 inches from chamber. While holding lamp end, remove lamp
socket from exposed lamp end.
4.
Carefully withdraw lamp from chamber. Be sure to withdraw lamp straight out without angling until completely
clear of quartz sleeve.
CAUTION: Lamp and quartz sleeve are easily damaged. Exercise care when handling.
5.
Reinstall lamp in reverse order.
WARNING: Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to water purifier until
lamp and both EASY-OFF
10
R
MIN-1, MIN-1.5,
EPLACEMENT
.10-0508B / 230
Figure 4 - Lamp Replacement
end cap by pulling cap off static gland nut.
TM
end caps have been properly reinstalled.
TM
AND
50/60H
V
Step 3 - Remove Socket
MIN-3
Z USING BALLAST NO
Step 1 - Disconnect Power to Water
Purifier and Remove Ground Connector
Step 4 - Remove Lamp
.10-0504B