11. Once the plumbing hook ups are made, it is a good practice to disinfect the "downstream" plumbing between the purifier and
point of use. This is done by introducing chlorine or other disinfectant solution directly into the purifier chamber, a 100-
ppm of chlorine is suggested. With the disinfectant solution in the purifier chamber, turn the ultraviolet purifier on. Open
the "downstream" outlet until a chlorine or disinfectant solution odor is noticed. Close the outlet and allow the disinfectant
to remain in the plumbing for at least three (3) hours. Flush the plumbing with ultraviolet purified water; allow the water to
run for a minimum of 5 minutes before use (to ensure no chlorine or disinfectant solution smell can be detected), this will
allow the chlorine or disinfectant solution to be flushed through the pipes. CAUTION: For added protection, a suitable
drain pan must be installed under the purifier. The drain pan must be plumbed to an adequate, free flowing drain to
prevent water damage in the event of a leak. There are numerous leak detection/flood stop devices, available on the
market today, designed to stop the flow of water, reducing the chance of water damage due to leakage. For more details
regarding leak prevention and/or limiting damages due to leaks, please contact the factory.
I
: MIN-6
NSTALLATION
SAFETY EQUIPMENT REQUIRED TO PERFORM TASK
1.
Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there
is any damage to the purifier, power cord or plug. All models, of the MINIPURE
lamps packed separately. Keep the lamp aside for installation once the purifier has been properly installed.
2.
Units occasionally experience damage in shipment due to the fragility of the quartz sleeve. It is therefore recommended
to inspect the water purifier for damage to the quartz sleeve after it has been removed from the shipping carton. Each end
of the unit as well as the inlet and outlet should be viewed to see if the quartz sleeve has experienced damage. If the quartz
sleeve shows signs of damage it should be replaced before the purifier is pressurized. See "Quartz Sleeve Cleaning or
Replacement" in the "Maintenance" section for the proper method of replacing the quartz sleeve in your water purifier.
3.
The water purifier should be mounted horizontally on a flat dry surface. The purifier should not be solely supported by its
plumbing connections. Securing the water purifier using the optional wall bracket kit is recommended.
4.
The water purifier must be connected to the cold water line only. Inlet water temperature should not exceed 100
5.
It is recommended that a 5-micron sediment filter be installed, in line, prior to the water purifier. The sediment filter will
stop or trap large particulates from entering the water purifier. Particulates may cause damage to the quartz sleeve, as well as
interfere with the purifier's ability to disinfect the water. The sediment filter may also help to reduce the amount of routine
cleanings of the quartz sleeve.
6.
Shut off valves should be installed on both the inlet and outlet sides of the water purifier. The use of bypass valves is not
recommended. The shut off valves allow the purifier to be isolated from the water supply, which is required when
removing the quartz sleeve.
7.
Unions should be installed on both the inlet and outlet of the water purifier; this will allow easy removal of the water purifier
from the plumbing, if required. Apply Teflon
8.
When all plumbing connections are complete, allow water to enter the water purifier at a low flow rate, until the purifier is full.
Note: Close the purifier outlet valve to the pressure chamber. With the purifier pressurized, it should be checked for leaks.
Once it is determined that there are no leaks, the inlet valve can be fully opened.
Figure 5 - 230v 50/60Hz (ballast no. 10-0504A)
MIN-9 230
50/60H
AND
V
®
tape to threads of inlet and outlet ports to ensure a tight seal.
Z USING BALLAST NO
®
line of water purifiers, are shipped with the
9. Unpack the lamp and ballast. While holding
lamp end, carefully push lamp socket on.
Carefully slide lamp straight into the quartz
sleeve, without angling. Push the end cap on,
over the static gland nut.
CAUTION: Lamp and quartz sleeve are
easily damaged. Exercise care when handling.

Installation: 230v 50/60Hz (ballast no.10-0504A)

Continued on Pages 10 and 11