- ページ 10
浄水器 Atlantic Ultraviolet MIN-9のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Atlantic Ultraviolet MIN-9 16 ページ。 Germicidal ultraviolet water purifiers
Atlantic Ultraviolet MIN-9 にも: オーナーズマニュアル (16 ページ), オーナーズマニュアル (20 ページ)
Lamp Installation or Replacement MIN-6 and MIN-9 120v 50/60Hz using ballast
no.10-0508B / 230v 50/60Hz using ballast no.10-0504B
–
Step 2
Remove End Cap
1.
2. Remove EASY-OFF
3.
Pull lamp cord and carefully withdraw lamp approximately 2 inches from chamber. While holding lamp end, remove lamp
socket from exposed lamp end.
4. Carefully withdraw lamp from chamber. Be sure to withdraw lamp straight out without angling until completely
clear of quartz sleeve.
Lamp and quartz sleeve are easily damaged. Exercise care when handling.
5.
Reinstall lamp in reverse order.
Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to water purifier until
lamp and both EASY-OFF
10
Figure 4 – Lamp Replacement
IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY
EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.
Disconnect power to water purifier, and remove ground connector from the chamber.
End Cap by pulling cap off static gland nut.
TM
End Caps have been properly reinstalled.
TM
–
Step 3
Remove Socket
–
Step 1
Disconnect Power to Water
Purifier and Remove Ground Connector
–
Step 4
Remove Lamp