- ページ 11
アクセサリー Atlantic Ultraviolet SanidyneのPDF インストレーション オペレーション&メンテナンスをオンラインで閲覧またはダウンロードできます。Atlantic Ultraviolet Sanidyne 16 ページ。 Portable area sanitizer
Atlantic Ultraviolet Sanidyne にも: ユーザーマニュアル (12 ページ)
TECHNICAL SPECIFICATIONS
model:
Volts:
Amps:
Hertz:
Maximum Treatment Time:
Maximum Room Size:
Weight:
Dimensions:
Lamp Data:
Treatment times are based on ultraviolet dose of 30,000 microwatt-seconds per square centimeter at 254nm.
Wattage is lamp watts only and does not include ballast loss.
Ultraviolet output at 254nm at 100 hours and 80°F (approximate).
All specifications, dimensional data, etc are approximate and subject to change without notice.
OPTIONAL ACCESSORIES
Zenith™ ultraviolet Meter
A sensitive, hand-held, ultraviolet meter; used to check the intensity of aging ultraviolet lamps and survey rooms
utilizing air sanitizers to ensure that the ultraviolet radiant exposure of personnel within the treated area is within
acceptable limits. the Zenith
row ultraviolet bandpass filter in combination with the photodiode detector makes the the Zenith
to ambient lighting within the area being surveyed. the Zenith
battery and an internal battery-saver will automatically shut off the meter after 30 minutes of inactivity.
the Zenith
Part No. 30-0081 is the recommended meter for this application.
Tm
REPLACEMENT PARTS
Item
deScriPtion
no.
1
Germicidal Lamp
2
Ballast
3
Protective Storage Cover
4
Power Cord
5
Adjustable Headgear
6
Face Shield
7
Warning Sign 8.5'' x 11''
8
Fuse
Other replacement parts are available. Consult the Atlantic Ultraviolet Corporation for specific requirements.
Table 2 - Technical Specifications
Length: (Inches)
Width: (Inches)
Height: (Inches)
Lamp model:
Number of Lamps:
Power Consumption: (Watts/Lamps)
Ultraviolet Output: (Watts/Lamps)
Average Effective Life: (Hours)
ultraviolet meter provides accurate and easy-to read levels of intensity. A nar-
Tm
Table 3 - Replacement Parts
120V 50/60Hz
QTY
Part no.
4
05-0592
4
10-0137
1
40-0616A
1
35-1754
1
00-0094
1
00-0095
2
00-0098
2
35-0644
40-0625B1
40-0625B2
120V
220-240V
2.25A
50/60Hz
58'L x 58' W x 20'H
55W (220W Total)
21W (84W Total)
monitor is powered by a single 9-volt alkaline
Tm
non-rohS
220-240V 50/60Hz
QTY
Part no.
4
05-0592
4
10-0136
1
40-0616A
1
35-1767
1
00-0094
1
00-0095
2
00-0098
2
35-0644
40-0625B3
220-240V
RoHS
1.3A
1.3A
50/60Hz
50/60Hz
24 Hours
22 lbs.
12 3/4"
12 3/32"
30 1/2"
05-0592
4
10,000
insensitive
Tm
rohS
220-240V 50/60Hz
QTY
Part no.
4
05-0592
4
10-0035C-R
1
40-0616A
1
35-1767
1
00-0094
1
00-0095
2
00-0098
2
35-0644
11