- ページ 9

エアクリーナー Atlantic Ultraviolet Hygeaire Air DisinfectionのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Atlantic Ultraviolet Hygeaire Air Disinfection 12 ページ。 Atlantic ultraviolet air disinfection owner's manual

TROUBLESHOOTING

!
CAUTION: Always disconnect power to the fixture, before performing any service.
IMPORTANT: This fixture is to be serviced ONLY by qualified, and appropriately licensed, personnel.
Problem
Fixture not operating.
Germicidal lamp
not operating.

TECHNICAL SPECIFICATIONS

MODEL
Dimensions:
Electrical:
Total Ultraviolet Output:
Ultraviolet output at 254 nm at 100 hours and 80° F (approximate).
120v 50/60Hz and 220-240v 50/60Hz units are standard - specify when ordering. Consult factory
with other specific power requirements.
Use personal protection equipment, such as gloves; long sleeves with no gaps between cuffs
and gloves, and ultraviolet resistant face shield, if troubleshooting
Table 1 - Troubleshooting
Possible Cause
No electrical power...
Power connections, to fixture,
loose or disconnected...
Lamp(s) not installed...
Germicidal lamp not
properly seated...
Germicidal lamp faulty...
Ballast not functioning...
Interlock Switch open...
Interlock Switch faulty...
Table 2 Technical Specifications
Length:
Width:
Height:
Volts:
Amps (Max):
Frequency:
Corrective Action
Verify that the purifier is connected to a live power source.
Verify power connections to fixture are fully engaged.
Install lamp(s).
Confirm connection of lamp and lamp holder, make sure
connection is tight and lamp holder is making full contact
with lamp.
Swap suspect lamp, with lamp known to be good. If
suspect lamp does not operate, replace lamp.
Locate ballast and replace.
Confirm louver panel is closed and secured.
Replace Interlock Switch.
LIND 24-EVO
LIND 24-EVO-2PM
24"
4
1
/
"
2
7-
7
/
"
8
120v
220-240v
120v
.42A
.23A
.83A
50/60Hz
50/60Hz
50/60Hz
8.5 Watts
®
Hygeaire
.
24"
9"
7-
7
/
"
8
220-240v
.45A
50/60Hz
17 Watts
9