1. RECOMMENDATIONS
AND SUGGESTIONS
• The Instructions for Use apply
to several versions of this ap-
pliance. Accordingly, you may
find descriptions of individual
features that do not apply to
your specific appliance.
• The manufacturer will not be
held liable for any damages
resulting from incorrect or
improper installation.
• The minimum safety distance
between the cooker top and
the extractor hood is 650 mm
(some models can be installed
at a lower height, please refer
to the paragraphs on working
dimensions and installation).
• Check that the mains voltage
corresponds to that indicated
on the rating plate fixed to the
inside of the hood.
• For Class I appliances, check
that the domestic power supply
guarantees adequate earthing.
Connect the extractor to the
exhaust flue through a pipe of
minimum diameter 120 mm.
The route of the flue must be
as short as possible.
• Do not connect the extractor
hood to exhaust ducts carry-
ing combustion fumes (boilers,
fireplaces, etc.).
• If the extractor is used in
conjunction with non-electrical
appliances (e.g. gas burn-
ing appliances), a sufficient
degree of aeration must be
guaranteed in the room in or-
der to prevent the backflow of
exhaust gas. The kitchen must
have an opening communicat-
ing directly with the open air in
order to guarantee the entry
of clean air. When the cooker
hood is used in conjunction
with appliances supplied with
energy other than electric,
the negative pressure in the
room must not exceed 0,04
mbar to prevent fumes being
drawn back into the room by
the cooker hood.
• In the event of damage to
the power cable, it must be
replaced by the manufacturer
or by the technical service de-
partment, in order to prevent
any risks.
• If the instructions for installa-
tion for the gas hob specify
a greater distance specified
above, this has to be taken
into account. Regulations
concerning the discharge of
air have to be fulfilled.
• Use only screws and small
parts in support of the hood.
Warning: Failure to install
the screws or fixing device in
accordance with these instruc-
tions may result in electrical
hazards.
• Connect the hood to the mains
through a two-pole switch hav-
ing a contact gap of at least
3 mm.
2. USE
• The extractor hood has been