Emptying the dust compartment
Empty the dust compartment after each vacuum
cleaning or as necessary. For best results it is
recommended that the dust compartment is emptied
regularly.
• Press the locking catch and remove the dust
L)
compartment.
• Remove the filter holder from the dust
compartment by pressing the green catch with your
thumb.
• Empty the dust compartment. Tip - to prevent dust
escaping, hold a plastic bag securely around the dust
compartment and empty contents into bag. Wait 30
seconds for dust to settle before removing and
sealing bag. Clean and dry the the compartment if
required.
• Remove any particles from the Cyclone cone and
replace filter holder ensuring it is properly inserted
and fastened.
• Replace the dust compartment (reposition front
first as shown in the diagram) until the locking catch
clicks to engage. Do not try to force shut.
Cleaning the filters
There are two lifetime filters in your Cyclone Power.
Should you ever need to replace them, use only
original Electrolux filters.
Filter 1 / Cyclone Filter ref.EF102
Filter 2 / Washable, reusable HEPA Filter
ref.EF25a
M)
Cleaning of filter 1 when the filter
illuminates.
• Remove and empty the dust compartment as
detailed above.
• Remove the filter cassette from the filter holder.
• Pull the orange tag to remove the sponge filter from
cassette.
• Remove loose fibres and larger particles from the
filter.
• Hand wash the filter or place in washing machine
on a 40˚ C programme. Squeeze to remove excess
water and leave to air dry. The filter must not be
tumble-dried. Place the filter back into the filter
cassette and filter holder ensuring it is completely
dry. Replace the filter holder back into the Cleaner.
• To avoid damaging the cleaner, do not use it
without the filters in place. A safety device (orange
button) prevents the insertion of the dust compart-
ment if Filter 1 is not in place (Do not try to force
shut). If the light is still on, check for possible
blockages in the nozzle, tube or hose.
For healthier homes
For healthier homes
N)
O)
indicator
Cleaning of Filter 2 / HEPA Filter, when the filter
indicator illuminates.
• Open the filter cover and remove the filter.
• Rinse the inside (dirty side) of the filter under warm
tap water. Do not use cleaning agents and avoid
touching the delicate filter surface.
• Tap the filter frame to remove excess water. Repeat
the cleaning procedure at least four times and allow
the filter to air dry completely. The original filtering
performance is now restored. Place the dry filter
back into the cleaner and close the cover.

Troubleshooting

Power: If the cleaner does not start, disconnect from
mains, check plug, cable and fuses where
appropriate.
Blocked air flow and dirty filters: The cleaner
stops automatically if a blockage occurs in the
nozzle/tube/hose or if the filters or Cyclone cone are
blocked with dirt. Disconnect from mains and allow
the cleaner to cool for 20-30 minutes. Remove
blockage and/or clean the filters. Restart the cleaner.
The clearing of blocked hoses is not covered by the
guarantee. To avoid blockages and maintain suction
efficiency, the floor nozzles should be cleaned
regularly using the hose handle.
Water: If water is sucked into the cleaner the motor
must be changed at an Electrolux Service Centre.
This is not covered by the guarantee.
Electrolux decline all responsibility for all damages
arising from any improper use of the appliance or in
cases of tampering with the appliance.
Electrolux reserve the right to alter product
appearance and/or specifications without notice. Not
all models featured are available in all countries.
Electrolux vacuum cleaner features and accessories
are protected worldwide by Patents or Registered
For healthier homes
designs.
ANY PROBLEMS?
Don't understand the instructions?
DON'T TAKE
IT BACK TO THE SHOP
We are only a telephone call away.
CUSTOMER HELPLINE
08706 055 055
Local call cost Australia wide: 1300 369 333
9
Something missing?
Need more help?