Specifications
Output Power
Factory Ship Settings
THD
Frequency Response
DSP Elements
GUI Control
Audio Power Down (APD)
Level Control (Assignable)
Protection Circuits
Signal to Noise Ratio
Input Sensitivity
Input Impedance
Output Terminals
Power Requirement
Power Consumption
Dimensions
Weight
Optional Accessories
DPA-102PM - Networkable 2-Channel
50 Watts per Channel @ 8Ω
100 Watts per Channel @ 4Ω
Two CH 4Ω,
Front Panel Levels Active,
DSP Set to Flat & 0dB
0.2% at rated output
-3dB 20Hz @ 20kHz (DSP Filters Engaged)
Input Level, Output Level, Output Limiter, 5 Band Parametric EQ per channel, HI & Lo Cut Filters,
Delay 60mS per channel, Matrix mixer
Ethernet Base, On Board Web (No PC Software for Single Unit Monitoring or Configuration)
On Trigger Threshold: 5mV
Off, No Signal Sense, 30min
Front Panel (Removable Knobs and Security Cover)
GUI Control (PC, IPhone, Android, Password Protected)
Remote Wired (10K Ohm Based, Separate Return per CH)
Thermal, Short, Limiter
-100dB Below Rated Output (A-weighted)
RCA Unbalanced 750mV Balanced 750mV Euro Block PHX Type 3.5mm
RCA Unbalanced: 10kΩ
Balanced: 20kΩ
Euro Block PHX Type 5.08mm
100VAC – 240VAC, 50/60Hz
Standby Mode (Ethernet Active): 1 Watts, 22mA, 3.14 BTU
Idle Active: 12.5 Watts, 173mA, 41 BTU
Average Power: 4Ω (Audio Signal,
Max Power: 4Ω (Audio Signal, Peak), 384 Watts, 4.9A, 1310 BTU
8.5" x 1.75" x 13.5" (216mm x 45mm x 343mm)
4.9lbs (2.4Kg) Only Unit
DPA IP Discovery Software
DPA Global Monitoring Software
AA-YSUM: Passive Summing of Stereo Signal
WPD-VC10K: Potentiometer on Wall Plate for Remote Level Control
Rack Mount Kit: PA702-RMK