ΑIRTECHNIC
1. HARDWARE LAYOUT
N-L-Earth:
T1:
6-wired input, for interconnection with the system's thermostat. I t allows the
communication with the zone's control on the demand/ no-demand state in order the
set-point temperature to be established.
M:
2-wired input, for provision of the motor's supply of the control element (Grill or
power driven damper).
RL 1:
The electronic control panel has 1 voltage free relay, which acts as a dry
contact. I t is normally open and switches on, switches off according to the operation
mode set by the system's thermostat. Cabling of the relay will take place with Airzone
Type B Cable and in a tube separate from the rest of the cables connecting to the
electronic control panel.
2. POWER SUPPLY CONNECTION
The electronic control panel is supplied with 12Volts of direct current, supplied by a stabilized
Airzone source connected to the electricity supply with the European Union standard voltage
level: 230 volts of alternate current 50Hz.
3. THERMOSTAT
Airzone Free
Airzone Tacto Cordless
Airzone Cordless
The Free, Tacto Cordless or Cordless thermostats communicate by infra red rays with
receivers which are connected by type A cable to the electronic control panel in the following
way:
INTELLIGENT AIR-CONDITIONING
AIRZONE UNO – INSTALLATION MANUAL
UNO BOARD INSTALLATION INDEX
Direct input with 230VAC-50Hz European Union standard voltage.