ELECTRICAL SHOCK HAZARD
Serious injury or death may
occur.
Disconnect from electrical
supply before servicing this
product.
Fan System:
The fan system consists of two primary elements: Fan Blade and Motor
Problem
Fan won't run and makes no sound.
Fan motor won't run and makes a
humming sound.
Breaker trips or fuse blows when fan is
started.
Motor overheating and shutting off.
Restarting several minutes later.
Fan motor won't run and switch makes
soft clicking sound.
Water Systems:
The water delivery system consists of four primary elements: Water Hose, Float Assembly, Pump,
and Water Distribution Channel.
Problem
Floor at side of the unit is wet.
The unit overflows from reservoir.
Water leaking from drain valve.
Too many dry streaks in the pads.
Water spitting from the unit.
Pump motor will not run when switch
is turned on.
Page 13 of 16

TROUBLESHOOTING

Check
Power cord, extension cord, switches, and circuit
breaker.
Motor stalled (will not turn by hand).
Motor stall.
Check power source for min. 115v/10 amp.
Extension cord adequacy.
Extension cord gauge too small.
Inlet air obstructed or too close to wall.
Faulty motor.
Switch making good contact.
Check
Water inlet hose is loose at supply
hose.
Float valve hose is loose at bulkhead
fitting or at float valve.
Water pressure is too high to allow
float valve to shutoff (60psi max).
Float valve is not seating properly.
Make sure drain nut is secure.
Holes in water distribution tray are
blocked.
Hose connection loose.
Check switch, cord and circuit
breakers.
Solution
Reconnect power or extension cord.
Reset breaker.
Replace motor.
Replace motor.
Upgrade power supply.
Replace with heavier cord.
Replace with heavier cord.
Provide additional inlet clearance.
Replace motor.
Replace switch.
Solution
Tighten connections and/or replace
hose washers.
Tighten connections and/or replace
hose washers.
Reduce water pressure by adding an
inline pressure reducer.
Check float valve.
Replace float
Tighten drain nut.
Remove distribution tray and clean
Tighten hose.
Replace hose and washer.
Replace switch and reset breaker.