Simplified Load and Pitch Limit Charts
6-Module (60° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
17
RMxx05
5
23
RMxx10
0
28
RMxx10
-5
32
RMxx10
-10
37
RMxx20
-15
n/a*
-20
n/a*
-25
n/a*
6-Module (80° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
19
RMxx05
5
24
RMxx10
0
30
RMxx20
-5
32
RMxx20
-10
38
RMxx20
-15
n/a*
-20
n/a*
-25
n/a*
Simplified Chart Notes:
1) Modeler
software calculates "array pitch" referenced to the acoustic centerline axis of the module in the first (top most) array
®
position. To convert the Modeler
pitch number then add to this number one-half of the nominal coverage angle number of the module in the first array position.
See Figure 10.
2) n/a denotes that array frame pickup point is at maximum; additional pitch requires pull-back bracket with third attachment point.
3) n/a* denotes that WLL limits require use of pull-back bracket to reduce moment force loads; desired pitch may be possible using
additional pickup points of Extender Bars; please consult your local Bose Professional Systems Division Field Engineer or Technical
Support Specialist for additional information.
Figure 10. Modeler
Array Pitch versus Array Frame Pitch
®
Page 14
Installation and Safety Guidelines
Large Array Frame with Short Extender Bars (In Position): 6 Modules
Predicted
Array
Pitch
Modules
RMxx05
10.3
5.0
RMxx05
RMxx10
0.6
RMxx10
-2.9
-9.9
RMxx20
n/a*
RMxx20
n/a*
n/a*
Predicted
Array
Pitch
Modules
10.3
RMxx05
RMxx05
5.8
0.4
RMxx05
-1.5
RMxx10
RMxx20
-9.5
n/a*
RMxx40
n/a*
n/a*
array pitch number to the "array frame" pitch used in the above tables, take the Modeler
®
6-Module (70° Total V)
Desired
Pickup
Predicted
Pitch
Point
Pitch
10
17
10.7
5
23
5.5
0
29
0.1
-5
32
-2.6
-10
37
-9.6
-15
n/a*
n/a*
-20
n/a*
n/a*
-25
n/a*
n/a*
6-Module (85° Total V)
Desired
Pickup
Predicted
Pitch
Point
Pitch
10
16
10.2
5
22
5.0
0
27
0.6
-5
32
-3.8
-10
36
-9.8
-15
n/a*
n/a*
-20
n/a*
n/a*
-25
n/a*
n/a*
pro.Bose.com
6-Module (75° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
20
RMxx10
5
26
RMxx10
0
31
RMxx10
-5
34
RMxx20
-10
39
RMxx20
-15
n/a*
-20
n/a*
-25
n/a*
6-Module (90° Total V)
Array
Desired
Pickup
Modules
Pitch
Point
RMxx05
10
17
RMxx05
5
23
RMxx10
0
29
RMxx10
-5
32
RMxx20
-10
37
RMxx40
-15
n/a*
-20
n/a*
-25
n/a*
®
Predicted
Pitch
10.4
5.0
0.5
-4.9
-9.4
n/a*
n/a*
n/a*
Predicted
Pitch
10.8
5.5
0.2
-2.5
-9.6
n/a*
n/a*
n/a*
array