- ページ 8

セキュリティセンサー Elektor TAPIRのPDF コンストラクション・マニュアルをオンラインで閲覧またはダウンロードできます。Elektor TAPIR 15 ページ。 E-smog detector kit
Elektor TAPIR にも: コンストラクション・マニュアル (9 ページ)

Figure 9. PCB 2 and PCB 4 removed from the panel.
Next, fit the following components on PCB 3 using the previously
described soldering method:
1. C3 (10 µF; no marking, large SMD)
2. R1 & R4 (100 kΩ; marking: 1003)
3. R2 & R3 (10 kΩ; marking: 1002)
4. R5 (1 kΩ; marking: 1001)
5. C1 (10 nF; no marking, small SMD)
6. T1 (MMBT3904; marking: 1AM)
7. T2 & T3 (BC847, marking: 1F or 1FW)
Figure 10. Detail of PCB 3 with C1, C3, R1–R5, T1–T3 fitted.
Elektor "TAPIR" E-Smog Tester Kit | Construction Manual
8/15
Temporarily connect a 1.5-V supply voltage to the points indicated in
Figure 11 below.
Figure 11. AA battery connected as a temporary 1.5 V power supply. Note polarity!
Figure 12. Detail of the temporary battery connection.