Stage 2 – Initial function - Set-up
Press the MODE key for 10 seconds to enter the configuration menu. All the basic functions necessary for the correct
functioning of the equipment are entered during this Set-up function. To regulate see the paragraph on regulation.
Stage 3 – Normal function
On switching on the cycle is automatically activated. During the pause time the display shows alternately the time
remaining of the cycle and the mixer air pressure. At the same time the LEDs at the side of the display are
illuminated alternately.
↑
By pressing the
key it is possible to freeze the display of the mixer air pressure reading until the key is released.
↓
By pressing the
key it is possible to freeze the display of the timer reading until the key is released.
Stage 4 – Alarm function
In the alarm mode the display starts blinking displaying the error code (see the "troubleshooting" paragraph).
When the conditions have been restored, the RESET button must be pressed to return to normal functioning.
7.3 REGULATION
To regulate all the parameters, start the pump and press the MODE key for 5 seconds. Subsequently follow the
instructions given in the table below.
Pressing the MODE key passes from one option to the next.
PARAMETERS
DISPLAY
Cycle control
time
Pump recharge
time
Pause cycle
Inversion of
solenoid
command
N° of control
elements
Max. air
Min. air
Minimum oil
level
System start pre-
cycle
Cycles of fault
Alarm Status
DESCRIPTION
The max. time is set within which the delivery of
lubricant must be confirmed. The range of regulation is
00-60 seconds
Pause time for recharging the pump. The range of
regulation is 0.0-9.9 seconds.
Interval of time between one lubrication cycle and the
next. The count commences when the delivery of
lubricant is confirmed. Range of regulation is
00.00-99.59 minutes.
Relay function; 1 for NC,
0 for NO.
Number of elements installed with flow control. If the
value 0 is set, before entering in pause (pause time), all
the timeout time must pass. Range of regulation 0-99
elements.
Max. limit of mixer air pressure. Entering the value 0 the
alarm is disabled. Range of regulation 0.0-7.0 bar
Min. limit of air pressure. Range of regulation 0.0-7.0
bar.
Alarm function for minimum oil level.
Number of start cycles for system pre-lubrication. Range
of regulation 00-60.
Number of consecutive fault cycles needed for an alarm.
Set the action to take after an alarm:
1 = stop the lubrication cycles
0 =Do not stop the lubrication cycles
OPERATION
Enter the desired values using the
↑ and ↓ keys
Enter the desired values using the
↑ and ↓ keys
Enter the desired values using the
↑ and ↓ keys
Do not alter
Enter the desired values using the
↑ and ↓ keys
Enter the desired values using the
↑ and ↓ keys
Enter the desired values using the
↑ and ↓ keys
Entering the value 0 an error is
displayed but the VIP4Air
continues to operate.
Entering the value 1 an error is
signaled and the equipment stops.
Enter the desired values using the
↑ and ↓ keys bearing in mind
that the value of cycles entered
must be double that of the desired
value.
Enter the desired values using the
↑ and ↓ keys.
Enter the desired values using the
↑ and ↓ keys.
DEFAULT
5 s
1.5 s
User
discretion
1
Min. 1
Max. 8
User
discretion
User
discretion
1
6
2
1
7