- ページ 8
インバーター DROPSA 0086450のPDF ユーザー・メンテナンス・マニュアルをオンラインで閲覧またはダウンロードできます。DROPSA 0086450 8 ページ。 Hydraulic inverter
14.1 LUBRICANTS
NOTE: The pump is designed to operate with maximum NLGI 2 grade lubricants.
Use lubricants compatible with NBR gasket
The residual lubricant used for assembly and testing is NLGI 2 grade.
A comparison table is provided between the classification of NLGI lubricants (National
Lubricating Grease Institute) and the ASTM classification (American Society for Testing and
Materials) for greases for the values that concern the product.
For further information about the technical specifications and the safety measures to adopt,
refer to the product safety sheet (Directive 93/112/EEC) relative to the type of lubricant
selected and supplied by the manufacturer.
15. PRECAUTION
Compliance with the essential safety requirements and the provisions specified in the machine directive was checked by filling
out prepared check lists that are contained in the technical file.
Three types of lists were used:
Risk assessment (UNI EN ISO 14121-1).
Compliance with the essential safety requirements Machine Directive –EC 06/42).
Electrical safety requirements (EN 60204-1).
The following is a list of dangers which have not been fully eliminated but which are considered acceptable:
During installation there may be small low pressure oil seepage from the pump. Always use appropriate protective
clothing, gloves and take all necessary safety precautions.
Contact with lubricant during maintenance or filling of the reservoir. As per previous point, correct precautions must be
taken to protect from contact with lubricant.
Electric shock. All electrical connections must be carried out by a qualified electrician who has studied the connection
to ensure no electrical danger
Unsuitable Lubricant. Lubricant characteristics are indicated on the pump and in this user manual. In any case contact a
Dropsa Sales and Support engineer (if in any doubts, contact the Technical Department Dropsa SpA).
Lubricants with abrasive additives
Lubricants with silicone based additives
Petrol – solvents – inflammable liquids
Corrosive products
Water
Food substances
8
FLUIDS EXPLICITY NOT ALLOWED
Fluid
Wear of the components inside the pump
Pump seizure
Fire – explosion – damage to the gaskets
Pump corrosion - damage to people
Pump oxidation
They would be contaminated
GREASES
NLGI
00
0
1
2
Dangers
ASTM
400 – 430
355 – 385
310 – 340
265 – 295