Control Panel
MAINTENANCE
Warning!
Disconnect the unit from the power
supply before cleaning or servicing.
Filter Cleaning: The pleated air filter
must be checked regularly. The filter
itself should be vacuumed frequently to
control the build-up of soil. A dirty
filter will reduce the dehumidifier's
capacity and efficiency. Do not wash
the filter. Replace the filter when it has
been used on a mold remediation job and
when it shows signs or normal wear and
tear.
Coil Cleaning: As the coils accumulate
soil, their heat transferring properties are
reduced. This can diminish water
extraction and create undue pressure on
the refrigeration system.
The coils should be cleaned about every
8 to 12 weeks. If the Atlantic LGR
Dry Air Technology • 313 North Oak Street Burlington, Washington 98233
Toll Free U.S. & Canada: 888.755.9176 • Tel: 360.755.9176 • Fax: 360.755.9236
Dehumidifier is used in a dusty
environment, cleaning may need to be
accomplished more frequently. The
coils should be dry before the following
cleaning operation is performed.
Dry Method. Inject compressed air
through each coil. After removing the
dry particle contamination, a wet
cleaning process may be used.
Caution!
Do not use a hose to flush the coils
and do not permit water to leak
into the electrical compartment.
Wet method. Use a soft brush and soapy
water. If soils have been allowed to
accumulate over time, they may be dry
and hard. Soak time may be required to
dissolve and release these soils from the
coils. A spray bottle or a syringe can be
used to apply controlled amounts of
cleaning solution. After cleaning, make
sure that the drain port, the condensate
tray and drain tubing are free of any
residual soil.
Electrical Wiring & Cord: Inspect the
power cord periodically to make sure
that the insulation is in good condition.
Replace worn or damaged cords.
Remove the dehumidifier cover to
expose the wiring and components.
Inspect wires to assure that they are
secured away from the fan blade.
Repair or replace as needed.
Fan Motor: Carefully remove dust and
debris from the fan motor and blade
assembly whenever you remove the
unit's cover for interior cleaning.
Drain Hose: Inspect the gravity drain
hose to make sure it is in good condition.
The hose should be checked before your
Atlantic LGR Dehumidifier leaves the
shop and again before the unit is left on
the job.