Comfortable Airflow
Power-Airflow Dual Flaps
Power-Airflow Dual Flaps can flatten out during cooling
operation to deliver cool air to the corners of a room.
See page 7
Wide-Angle Louvres
The smoothly curved Wide-Angle Louvres provide wide
airflow coverage for effective operation no matter where
the indoor unit is placed in a room.
See page 7
Vertical Auto-Swing (up and down)
This function automatically moves the flaps up and down
to distribute air across a room.
See page 4
Horizontal Auto-Swing (left and right)
Horizontal Auto-Swing automatically moves the louvres
to the left and right to cover a room with cool air.
See page 4
3-D Airflow
This function combines Vertical and Horizontal Auto-
Swing to circulate a cloud of cool air right to the corners
of even large spaces.
See page 4
Lifestyle Convenience
New Powerful Operation
New Powerful Operation boosts airflow to maximum
volume for a 20-minute period. After this, the unit
automatically returns to its previous settings.
See page 7
Indoor Unit On/Off Switch
The unit can be conveniently started manually in the
event the wireless remote controller is misplaced or the
wireless remote controller batteries are not charged.
Cleanliness
Air-Purifying Filter with Photocatalytic
Deodorising Function
This filter traps microscopic particles, decomposes
odours and even removes bacteria and viruses. It can be
used for up to 3 years .
See page 6
Wipe-Clean Flat Panel
The flat panel models can be cleaned with only the single
pass of a cloth across their smooth surface. The flat panel
can also be easily removed for more thorough cleaning.
See page 5
Comfort Control
Programme Dry Function
This function automatically reduces the level of humidity.
Auto Fan Speed
The microprocessor automatically controls fan speed to
adjust the room temperature to the set temperature.
Timers
24-Hour On/Off Timer
This timer can be preset to start and stop at any time
within a 24-hour period. The air conditioner is
started/stopped simply by pressing the On/Off/setting
timer button on the wireless remote controller.
Night Set Mode
Pressing the Off timer button automatically selects Night
Set Mode. Room temperature is raised by 0.5 C after 60
minutes to prevent excessive cooling for your pleasant
sleep.
See page 7
Worry Free
Auto-Restart After Power Failure
The air conditioner memorises the settings for mode,
airflow, temperature, etc., and automatically returns to
them when power is restored after a power failure.
Self-Diagnosis with Digital Display
Malfunction codes are shown on the digital display panel
of the wireless remote controller for fast and easy
maintenance.
See page 8
Anticorrosion Treatment of Outdoor Heat
Exchanger Fins
The outdoor unit's heat exchanger fins are processed
using a special anticorrosion treatment. The surface is
covered with a thin acrylic resin layer to enhance the fins'
resistance to acid rain and salt corrosion.
See page 8
9
Indoor unit
Model name
Outdoor unit
kW
Capacity
Btu/h
Power supply
Running current
A
Power consumption
W
COP
W/W
Indoor unit
Front panel colour
Airflow rate (H)
m
/min (cfm)
3
Fan speed
Sound levels (H/L)
dB (A)
Dimensions (H x W x D)
mm
kg
Machine weight
Outdoor unit
Casing colour
Type
Compressor
Motor output
W
Refrigerant charge (R-410A)
kg
Sound levels
dB (A)
Dimensions (H x W x D)
mm
Machine weight
kg
Operation range
CDB
Liquid
Piping connections
Gas
mm
Drain
Max. piping length
m
Max. height difference
Note: The above values are based on operation with a 220V, 50Hz power supply.
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Sound levels are based on temperature condition in 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual
opration as a result of ambient conditions.
No.
Item
1
Air-purifying filter with photocatalytic deodorising function without frame
2
Remote controller loss prevention with chain
Notes: *1. The filter is a standard accessory. It should be replaced after approximately every 3 years.
Air-purifying filter with photocatalytic
Remote controller loss
prevention with chain
deodorising function without frame
KKF917A4
KAF952A42
No.
Item
1
Air direction adjustment grille
2
Drain plug
FTN50JV1
FTN60JV1
RN50JV1
RN60JV1
5.3
6.7
18,090
22,860
1 phase, 220-240 V, 50Hz
7.5
10.2
1,640
2,210
3.23
3.03
FTN50JV1
FTN60JV1
White
17.5 (618)
18.5 (653)
5 steps and automatic
45/35
47/36
290 x 1,050 x 238
12
RN50JV1
RN60JV1
Ivory white
Hermetically sealed rotary type
1,300
1,700
1.6
2.0
50
52
735 x 825 x 300
770 x 900 x 320
48
63
19.4 to 46
6.4
12.7
15.9
18.0
30
20
Indoor unit
FTN50/60JV1
*
KAF952A42
1
KKF917A4
Outdoor unit
RN50/60JV1
KPW945A4
KKP937A4
Specifications are subject to change.