- ページ 3

ドライヤー DryMax MHT100A-1のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。DryMax MHT100A-1 12 ページ。 Mht series high inlet temperature refrigerated air dryers

RECEIVING AND INSPECTION

1. The dryer cannot be tilted on its side or upside down during shipping.
2. Use forklift from the bottom of the dryer when installing or moving.
3. Dryers are shipped F.O.B. factory. Immediately upon arrival check the dryer for possible
damage. If damage is found, report it to the carrier and file a damage claim.
4. Check dryer data label to be sure you have the right dryer. Check the data labels voltage and
amperage to be sure it is correct and the one you ordered.
5. Check the refrigeration gauges for pressure. If gauges read 0 PSIG STOP. Do not start dryer. Call
your distributor for service. This could mean there is a leak and the refrigerant has leaked out.
HOW THE AIR DRYER WORKS
MHT Series refrigerated compressed air dryers use refrigeration cooling to condense entrained
moisture out of the compressed air stream. Warm saturated air enters the air-to-air heat exchanger
at the dryer inlet. (1)
In the air –to- air heat exchanger the inlet air is pre-cooled by the outgoing cold air. The
pre-cooled air then enters the air to refrigerant heat exchanger (3) were it is cooled to its lowest
point by the refrigeration in the evaporator. As the air is cooled moisture in the air changes from
a vapor to a liquid. The liquid condensate is removed from the airstream by the separator (4)
and discharged from the dryer by the automatic drain valve. (5) The cold air is reheated by
incoming warm air as it passes back through the air-to-air heat exchanger. Pre-cooling the inlet
air reduces the heat load on the refrigerant compressor, permitting the use of a smaller refrigerant
compressor. (2) The out going cold air is reheated by the in coming hot air. As a result the outlet
air is warmed up as it leaves the dryer. This prevents the outlet pipe from sweating. The air exits
the dryer and is now clean and dry, ready for use.