- ページ 7

炉 DS Greenhouse Blast GH450のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。DS Greenhouse Blast GH450 13 ページ。 High efficiency wood or coal furnace

DS Pneumatic Powered Thermostat Kit
This thermostat is designed for use with a wood or coal furnace only. It will not take the place of proper furnace
management. You will get the best response from this unit if you service your furnace according to the manu-
facturers recommended practices, Your Air Supply needs to be clean and dry.

Installation Instructions

A - Install cylinder approx. 24" above and center of draft inlet lid with #14 x 3/4 self drilling screws. Fasten chain
with no slack when cylinder is extracted.
B - Mount air regulator and thermostat 50 – 70 feet from furnace.
C - Connect 5/32 air hose from regulator to "in" on thermostat. Then from "out" of thermostat to cylinder at
furnace as per diagram. Air regulator needs to be set at 20psi.
D - Test the unit after installed to make sure draft lid opens and closes properly. Then build your fire in furnace,
and set thermostat to desired temperature.
Air Regulator
set at 20psi
Air Supply
5/32 Air Hose

Parts List

DSM61236NH . . . . . .5/32 Nylon Hose
DSMIUHH2 . . . . . . . .Thermostat
DSMAR2000-02 . . . . .Air Regulator
DSMK4515 . . . . . . . . .Gauge for Air Regulator
DSM75RSR . . . . . . . .Cylinder
DSMCLEVISKIT . . . . .Clevis Kit for Cylinder
DSMMOUNTBKT . . . .Mount for Cylinder
DSMCYLFITTING . . .Push-Lok fitting for Cylinder
Thermostat
50 - 70 feet
from Furnace
5/32 Air Hose
7
Mount
Cylinder
on side of
Furnace
Attach Chain to
Draft Inlet at
side of Furnace
24"
Chain