Step
2. For models without auto-
swing (right and left)
1
Unfasten the hooks at
the upper 2 positions.
2
Unfasten the 3 hooks of
the vertical blade ASSY
by pressing them with a
flat screwdriver.
3
Remove the vertical
blade ASSY.
4
Remove the other
vertical blade ASSY in
the same way.
Removal Procedure
Procedure
Hook
Vertical blade ASSY
Hook
Vertical Blade ASSYs
Points
Each vertical blade ASSY
has 5 or 6 fins which can not
be replaced individually.
The vertical blade ASSY is
not marked for difference
between right and left.
(R18194)
(R8022)