- ページ 7
屋外ライト Daintree GE Current Lumination Tetra Contour 75487 SeriesのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Daintree GE Current Lumination Tetra Contour 75487 Series 7 ページ。
Lumination
(Tetra
®
Troubleshooting
Symptom
No AC input
All LEDs are OFF
Incorrect wire attachment
Overload (maximum load
exceeded)
Some LEDs
Maximum recommended supply
appear dim
wire length exceeded
Mixed Suffix Codes of LED light
engine within an application
Some of the sections
Incorrect wire attachment
are not illuminated
Light/dark banding
LED light engine stretched
along a section
during installation
Loading Chart
LED Driver
79045 (GE080/MV/D24T1-A)
67825 (GEPS24-100UGL-IP)
62189 (GE180/MV/V24T1-C)
Remote Mounting Distance
LED Driver
79045 (GE080/MV/D24T1-A)
67825 (GEPS24-100UGL-IP)
62189 (GE180/MV/V24T1-C)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAN ICES-005 (A) / NMB-005 (A)
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Contour - Series)
®
Condition
Attach AC input and/or check circuit breaker
Check wire connection(s) at the Tetra Contour LED light engine and power supply for im-
proper connections or short circuits. Make sure you have positive to positive and negative
to negative wire connections.
Ensure the overall length of Tetra Contour LED light engine does not exceed the maximum
load as detailed in the Tetra
Reduce the length of supply wire equal to or below the recommended maximum.
Make sure that all LED light engines have the same Suffix Code
(Suffix Code is located on each packaging label).
Check the wire connections at the Tetra Contour LED light engine for improper connec-
tions. Make sure you have positive to positive and negative to negative wire connections.
Check for improper cutting resolution locations (see Item 21 on Page 2).
Remove LED light engine and properly install.
Inspect and replace light engine if the silicone is damaged.
Minimum Loading
8 in. (0.20m)
8 in. (0.20m)
8 in. (0.20m)
18 AWG (0.82mm
Supply Wire
1-20 ft. (0.3-6.1m)
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
ARCH018 (Rev 04/02/2021)
Power Supply Installation Instructions.
®
Maximum Loading
White Colors
22 ft. (6.69m)
27 ft. (8.19m)
25 ft. (7.59m) per Bank/
50 ft. (15.18m) per Driver
)
16 AWG (1.31mm
)
14 AWG (2.08mm
2
2
Supply Wire
30 ft. (0.3-9.1m)
Installation Guide
Solution
Maximum Loading
RGB Colors
50 ft. (15.24m)
59 ft. (17.98m)
55 ft. (16.76m) per Bank/
110 ft. (33.53m) per Driver
)
12 AWG (3.31mm
2
Supply Wire
Supply Wire
50 ft. (0.3-15.2m)
86 ft. (0.3-26.1m)
)
2