- ページ 2
屋外ライト Daintree GEF60SGNHOLED-1のPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Daintree GEF60SGNHOLED-1 4 ページ。 Led lighting system
LineFit Light-LED (LFL-LED)
Components
2
1
5
6
Installation
Prior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure that the branch
circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power supply, and have a current rating not
exceeding 20A, or that permitted by applicable local, state, or country electrical codes (whichever is less).
If removal of the existing lighting equipment (see Step 2) eliminates the disconnect switch, as required by applicable local, state, or country
electrical codes; a new disconnect switch must be installed.
If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state, and country electrical codes.
Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) diameter require a metal patch
secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-hardening caulk.
NOTE: If component 6 is necessary, refer to 32619 LFL-LED Coupler2 Line Fit Light Coupler-2nd Gen Installation Guide. If component 7 is necessary,
refer to 33125 LFL-LED Sockets LineFit Light Sockets Installation Guide.
1
Turn off power and remove panel
from fluorescent box sign.
The existing socket should be push-in
double contact lamp holder
LEDs face
front of sign
Pull and twist endcap fitting
to align with lamp holder
4
Orient Line Fit Light so LEDs are facing
front of sign, then pull and twist the
two endcap fittings so they align with
existing fluorescent lamp holders.
4
3
T
Measure Point
C
8
7
Remove old components
2
Remove old fluorescent tubes,
ballast and wiring. DO NOT remove
existing fluorescent lamp holders.
NOTE: Follow all federal and
local regulations when disposing
of neon tubing, fluorescent tubes,
transformers and ballasts.
5
Push Line Fit Light into existing
fluorescent lamp holders.
UL certified 18 AWG (0.82 mm
1
2
UL certified 22-14 AWG (0.33-2.08 mm
or 22-18 AWG (0.33-0.82 mm
End caps
3
Tetra
24 Volt Power Supply
4
®
LineFit Light-LED (LFL-LED) modules
5
6
32619 LFL-LED Coupler 2 Line Fit Light Coupler-2nd Gen (optional)
93020091 LFL-LED Sockets LineFit Light Sockets (optional)
7
Electrical grade RTV silicone.
8
Example electrical grade RTV silicones include:
• Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant
• Momentive White Blanc RTV 162 Silicone Rubber Adhesive Sealant-
Electrical Grade
• Dow Corning 3140 - Non-Corrosive Flowable (clear)
• Dow Corning 3145 - Non-Corrosive Nonflowable (clear or gray)
• Dow Corning RTV 748 Non-Corrosive Sealant-White
Old Fluorescent tube
or F48T8HO
3
Read the product labels to
determine Line Fit Light length
required to span width of
sign based on table in the
Specifications section (last page).
6
Continue installing Line Fit Light
fixtures.
2
Installation Guide
) supply wire
2
) wire connectors
2
) inline/IDC connectors
2
New LED retrofit
F48T12HO