- ページ 4

屋外ライト Daintree GEF72DHOLED-1のPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Daintree GEF72DHOLED-1 4 ページ。 Led lighting system

Daintree GEF72DHOLED-1 インストレーション・マニュアル
LineFit Light-LED (LFL-LED)
Troubleshooting
Symptom
Row of fixtures does not light
Sign does not light
Individual fixture does not light
Specifications
Product Code
Description
32500, 32520, 32553
GEF18xxxHOLED-1
32501, 32527, 32554
GEF24xxxHOLED-1
32502, 32528, 32557
GEF30xxxHOLED-1
32504, 32529, 32560
GEF36xxxHOLED-1
32505, 32531, 32572
GEF42xxxHOLED-1
32511, 32532, 32573
GEF48xxxHOLED-1
32513, 32533, 32574
GEF60xxxHOLED-1
32515, 32535, 32579
GEF64xxxHOLED-1
32516, 32538, 32587
GEF72xxxHOLED-1
32517, 32547, 32588
GEF84xxxHOLED-1
32518, 32548, 32607
GEF96xxxHOLED-1
Power Supply Loading
Description
Long Description
GEPS24-100U-GL
Power Supply (24VDC / 96W), Input Voltage: 108-305VAC; Damp Rated;
Self-Contained, Remote or Raceway; 1 Output Bank; Class 2
GEPS24-100U-GLX
Power Supply (24VDC/96W), Input Voltage: 108-305VAC; Damp Rated;
1 Output Bank; Class 2
GEPS24-100U-NA
Power Supply (24VDC / 96W), Input Voltage: 108-305VAC; Damp Rated;
Self-Contained, Remote or Raceway; 1 Output Bank; Class 2
GEPS24-180U
Power Supply (24VDC/180W), Input Voltage: 90-305VAC; Damp Rated;
Self-Contained, Remote or Raceway; 2 Output Banks of 90W each; Class 2
GEPS24D-80U
0-10V Dimming Power Supply (24VDC/80W), Input Voltage: 90-305VAC;
Damp Rated; Self-Contained, Remote or Raceway; 1 Output Bank; Class 2
GEPS24W-80
Power Supply (24VDC/80W), Input Voltage: 90-264VAC; Wet Location Rated;
1 Output Bank; Class 2
GEPS24-300U-GL
Power Supply (24VDC/288W), Input Voltage:108-305VAC; Damp Rated;
Self-Contained, Remote or Raceway; 3 Output Bank; Class 2
If you have any questions about these instructions or your specific application, please contact support at [email protected].
This product is intended solely for the use of non-residential signage lighting and is not intended for use in any other applications.
Solution
• Check wire connections to power supply to ensure red stripe-to-red and white-to-black connections.
• Check row-to-row polarity connections.
• Check input and output voltage and check power supply input/output connections.
• Check polarity connections.
• Remove fixture and replace with another working fixture.
Long Description
18'' Sign White, Daylight, Cool White LED Lamp
24'' Sign White, Daylight, Cool White LED Lamp
30'' Sign White, Daylight, Cool White LED Lamp
36'' Sign White, Daylight, Cool White LED Lamp
42'' Sign White, Daylight, Cool White LED Lamp
48'' Sign White, Daylight, Cool White LED Lamp
60'' Sign White, Daylight, Cool White LED Lamp
64'' Sign White, Daylight, Cool White LED Lamp
72'' Sign White, Daylight, Cool White LED Lamp
84'' Sign White, Daylight, Cool White LED Lamp
96'' Sign White, Daylight, Cool White LED Lamp
For the latest install guides for your product go to: www.gecurrent.com
Conforms to the following standards:
www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without
notice. All values are design or typical values when measured under laboratory conditions.
SIGN182 (Rev 02/11/21) GE2028-6426
Installation Guide
III
Ft
Rating (Watts)
1.5'
8.64
2'
11.52
2.5'
14.4
3'
17.28
3.5'
20.16
4'
23.04
5'
28.8
5.33'
31.68
6'
34.56
7'
40.32
8'
46.08
Ft per PS
16'
16'
16'
14' per Bank
12'
12'
16' per Bank