- ページ 4

タイマー DSAN Limitimer ASL4-ND3BTのPDF マニュアルをオンラインで閲覧またはダウンロードできます。DSAN Limitimer ASL4-ND3BT 5 ページ。 Speaker timer with remote signal light

DSAN Limitimer ASL4-ND3BT マニュアル
Signal Light Settings
Use DIP switches on the bottom of the signal light
to set which timer programs to display, whether
sound cues accompany light changes, which phase
lights are active and how the digital display
behaves. All settings are local can can be different
for each signal light connected to the timer.
Default Settings
DIP switches on
on
bottom of signal light
1 2 3 4 5 6 7 8 9 10
1-4. Select Timer Programs to be displayed
1. Display Program 1 [ON]
2. Display Program 2 [ON]
3. Display Program 3 [ON]
4. Display Program 4 [ON] (Session)
Since Program 4 can run in background, it might be
useful to use a separate signal light that is enabled
for Program 4 ONLY and another that is enabled for
Programs 1, 2 and/or 3 ONLY. A signal light that is
enabled for multiple programs displays the program
that is selected on the timer.
5. Continue counting after zero [ON] else, stop
display at zero. Note, in OFF mode, the clock
continues to run and red light stays on until user
presses "Stop." Beep / Blink continue, if set.
6. Sound volume. High [ON] Low [OFF]
7.+ 8. Sound Selection
7. ON 8. ON None*
7. OFF 8. ON Buzz
7. ON 8. OFF Ring
7. OFF 8. OFF Chime
9. Display top lights [ON]
10. Display digits [ON]
Display Lights:
Switch 9 =ON
Front lights
always active
Depressed position = ON
*An empty sound. "Beep"
pressed on the timer
outputs a cue to activate a
sound at a signal light that
is set for an audible sound.
Display Digits:
Switch 10 = ON
Signal Light Connections
Connect the signal light to the Limitimer console
with the 50-foot Cat-5 cable or the Cat-5–XLR
adapter (both included).
If Limitimer is used in debates or contests where
separate times are maintained for participants, set
the signal lights each to receive only a unique
program. Signal lights may be interconnected to
the timer console along a single cable run.
Caution: Cables carry 12V power.. Do not connect
to audio devices or data ports. Contact DSan for
pinouts to make your own cables.

Network Connections

Use IP-2000X "Network Extender" to make timer-
signal light connections over a network. For more
information, see www.dsan.com/Network .
Program 1
Program 2