- ページ 7
セキュリティシステム DSC PC1550のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。DSC PC1550 9 ページ。 4 digit master code
DSC PC1550 にも: 取扱説明書 (17 ページ), 取扱説明書 (17 ページ), 取扱説明書 (17 ページ), 取扱説明書 (17 ページ), 取扱説明書 (12 ページ)
1
2
3
4
5
6
F
A
P
TEST SYSTEM WEEKLY
Press [F] for 2 seconds to activate
FIRE transmission.
Press [A] for 2 seconds to activate
an AUXILIARY transmission.
Press [P] for 2 seconds to activate
PANIC transmission.
THESE BUTTONS WILL NOT FUNCTION
UNLESS PROGRAMMED BY YOUR
INSTALLER.
1
2
3
4
5
6
7
8
9
0
#
F
A
P
8
Ready
Armed
Memory
Bypass
Trouble
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Press [#].....
.....
.....
.....
.....
When an error is made in
entering code, then enter
code again.
To return to ready state
*
after using [
] commands.
Ready light ON - System is ready for
arming.
Ready light OFF - System has an open
zone which must be closed or bypassed
before arming.
Armed light will come ON indicating the
system is armed. To arm, ensure "Ready"
light is ON - enter 4 digit code.
Memory light ON means an alarm has
*
occurred. Press [
] then [3]. Zone light will
come ON to indicate which zone caused
the alarm.
Bypass light comes ON when you bypass a
zone. To bypass a zone, press [
*
then the zone(s) you wish to bypass. Enter 1
for zone 1....6 for zone 6. Press [#] to return to
Ready.
Trouble light is ON when there is a fault in
Trouble
Trouble
Trouble
Trouble
the system. Press any key to silence the
keypad beeping. Press [
*
] then [2] to
display the trouble type .
Zone Light
Trouble Type
1 ............. Low battery
2 ............. AC fail (buzzer does not sound)
3 ............. Fuse open (BELL or AUX fuse)
4 ............. Fail to communicate
5 ............. Fire loop(s) trouble
6 ............. Clock needs resetting
Zone
Zone
Zone light(s) when ON in the disarmed mode,
Zone
Zone
indicate an open zone. e.g. open door,
window, etc. Refer to zone chart on the
keypad door for zone information.
9
][1] and