8.1 Testing the detection zone

1. Mount the detection module and the lens on the back box.
2. Close the detector and tighten the locking screw.
3. Put the control panel in test mode by entering the following:
master code
4. Check the detection zone using the LED and adjust if necessary.
Each time something is detected, the control panel issues the
voice message: "Beep, deterrence detector X" (depending on the
configuration).
5. Put the control panel back in installation mode by entering:
installer code
6. Open the detector, set the infrared sensitivity if necessary and then
close it.

8.2 Performing a real test

1. Put the control panel in user mode by entering:
installer code
2. Put the control panel in Total Arm mode.
3. Wait 120 s for the detector to become activated.
4. Walk across the protected area and check the control panel
response (see control panel installation manual).