- ページ 7
セキュリティシステム DAITEM SH401AXのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。DAITEM SH401AX 9 ページ。 Indoor siren
7. Maintenance
7.1 Fault indications
The control panel supervises and identifies the siren.
It monitors the state of the:
• power supply,
• radio link,
• tamper contact.
If a fault is memorised the control panel issues a voice message to indicate the fault following a system command
(see § Fault indications in the control panel installation manual).
7.2 Changing the battery
• The lithium battery pack must be replaced by the same type of pack with the same technical characteristics,
i.e. 2 x (3.6 V – 13 Ah).
• We advise you to use the DAITEM BatLi22 pack available in the catalogue in order to guarantee individual safety
and equipment reliability.
• Dispose of the waste lithium power pack in an appropriate recycling bin.
To change the battery:
1. send a disarm command,
2. switch the control panel to installation mode:
master code
3. remove the siren from the wall,
4. remove the faulty lithium power pack,
5. wait for 2 minutes before connecting the new lithium pack,
6. close the siren and put it back on its base,
7. switch the control panel to user mode:
installer code
8. test triggering.
8. Summary of parameters
Parameter description
Delayed sounding
upon intrusion
Sounding duration
Sound level of disarm/arm
indications
Transfer of disarm/arm
indications
Indication of audible signals
and door bell
Validation of radio link
in installation mode
Triggering upon intrusion
Protection system armed
indication
Alarm indication in armed
presence mode
Triggering upon
communication network
interruption
Radio tamper
Allocation of a siren to one
or several intrusion groups
Deletion of all parameters
Deletion of one parameter
then
installer code
Parameter-setting sequence
** 4 * siren n° * 3 * ?? **
** 4 * siren n° * 4 * ??? **
** 4 * siren n° * 11 * ? **
** 4 * siren n° * 12 * ? **
** 4 * siren n° * 13 * ? **
** 4 * siren n° * 15 * ? **
** 4 * siren n° * 20 * ? **
** 4 * siren n° * 21 * ? **
** 4 * siren n° * 22 * ? **
** 4 * siren n° * 26 * ? **
** 4 * siren n° * 27 * ? **
** 4 * siren n° * 37 * ? **
** 4 * siren n° * 197 ***
** 4 * siren n° * parameter n° ** 0 **
Factory
parameter
0: immediate
from 0 to 60 s
0: immediate
90 s
from 20 s to 180 s
4: average
from 1 to 8
1: sound
0: disabled
1: sounding
1: enabled
0: disabled
1: enabled
0: on one
0: validation on 1 of 2 bands
of 2 bands
1: validation on 2 bands
1: single
0: disabled
or confirmed
1: single or confirmed intrusion
intrusion
2: confirmed intrusion only
1: audible
0: disabled
1: sounding
2: loud sounding
0: disabled
(15 s)
1: quiet sounding (4 beeps)
2: loud sounding (15 s)
0: disabled
0: disabled
1: loud sounding triggered if the system
is totally armed
2: loud sounding triggered 24/24
1: enabled
0: disabled
1: enabled
all groups
Selection of group(s): from 1 to 8
depending on type of control panel
-
-
-
-
7
Li
Possible values
Page
3
3
4
4
4
4
4
4
4
4
5
5
5
5