3.Mounting Method
3-2
Output derating
HFS150A-12
100
80
60
40
20
0
1 0
-10
0
Ambient Temperature (degree C)
HFS150A-24、30、48
100
80
60
40
40
20
0
1 0
-10
0
Ambient Temperature (degree C)
4.Connections
・ Please be away among Output load wire, remote control wire, remote sensing wire and input wire
in order to minimize noise interference. If you twist the each wire, it will improve.
・ You can add lower value of electrolytic capacitor to the load edge for noise removal.
・ Do not wire for the output load wire lengthening it more than the necessity.
・ Please connect the terminal
equipped with the power supply shortest in the thick wires for safety and the noise removal.
There is fear of the electric shock.
・ Recommended tightening torque of I/O terminal screw (M4) : 1.4N・m
・ Wrong wiring or wrong connections are become the cause of damage when you use the remote
sensing function. Connect it very carefully with the input intercepted.
5.Trouble shooting before contact us
・ Please make sure your input voltage.
・ Please make sure your input/output connections.
・ Please make sure your wire specification.
・ Check the output adjustment potentiometer.
Sometimes OVP function turns off the output power when you turn the potentiometer too much.
・ Check the capacitance at the load side is not too much.
・ Check the remote control on/off.
・ Check the switch is "1" when the remote sensing is not used.
(a)、(d)
(b)
(c)
2 0
3 0
4 0
5 0
(a)、(d)
(b)
(c)
2 0
3 0
4 0
5 0
with the frame ground terminal of the equipment and the device
3-3
Notes of mounting
・ This power supply is the natural convection
cooling.
・ Please secure ventilation by leaving space
between power supplies when you use two
or more, so as not to exceed the temperature
span that the ambient temperature shows in
the derating table[3-2].
6 0