TR8200 Thermostat User Manual
LCD Symbols
Symbols
Description
Turning on/off the thermostat
The buttons are locked
Heating is turned on
Frost protection activated
RT
Room temperature
FT
Floor temperature
AUTO
Automatic mode, executes the programmed schedules
Temporary temperature override
O / RIDE
Err
The sensor is not being read by the thermostat

Configuration Menu

To enter into menu settings,
touch
Then you will see menu 01. Touch
Features description
Menu #
01
Model selection
02
Switching differential
03
Calibrate the room temperature To compensate for any difference between the displayed room temperature and a thermometer
04
Calibrate the floor temperature
05
Maximum floor temperature
06
Backlight turning-on time
07
Temperature format
08
Clock format
09
Frost protection
10
5+2 /7 Day program mode
11
Key click sound
Software version
12
Hidden menu
13 , 14
Setting the clock and day of the week
This thermostat is fitted with a real time clock. It is essential that the clock time and day are set accurately if you require your programmed events to start on time. Follow below steps,
1) Touch time display .
Use
or
2) Touch day display .
Use
or
Select the required operating mode
Auto - Automatic mode, the thermostat executes the preprogrammed schedules. To adjust these schedules, see page 2 the program section.
In addition to Automatic mode, this thermostat has 3 extra manual modes, i.e
- Comfort temperature mode, the highest temperature you want to achieve, this is the temperature that will be required when the room is in use. Default is 22 °C.
- Economy temperature mode, the lowest temperature, the temperature you want to go no lower than when the room is not in use. Default is 16 °C.
- Vacation temperature mode, this is set to stop your floor from going below the set temperature. Default is 10 °C.
To change the set temperatures, touch temperature display. Use
to turn thermostat off, and now touch
Next
or
Previous
to select the menu number. Use
Features Explanation
This thermostat is a combination model allowing you to choose among 3 models.
A model:
air only , with built in sensor
AF model:
air & floor, with both built in and remote sensor
F model:
floor only
, with remote sensor
The numbers of degree difference before switching. The default is 1°C which means
the thermostat will switch the heating on 0.5°C below the set temperature and will
turn it off 0.5°C above the set temperature.With a 2°C differential, the heating will
switch on 1°C below the set temperature and switch off 1°C above the set temperature.
To compensate for any difference between the displayed floor temperature and a thermometer
This is to protect the floor surface by limit the floor temp.
To set the backlight turning-on time when the screen is pressed.
This allows users to select between °C or °F.
12 Hour or 24 Hour clock format selection
This is to avoid room temperature goes below 5°C
This allows you to program either 5 days at once, then the 2 days of the weekend
separately, or a full 7 days at the same time or 7 days separately
Choose whether or not a key click sound is audible when you press the LCD screen
This is to view the current software version
press and hold"OFF"for 5 seconds in standby mode, and you can set the min. and max. room temperature
to change the time. Press and hold
to change the day. Touch
Done
See overl1eaf for further setting up information
Symbols
Description
Day of the week.
Day
Program 1,2,3,4
The program number
Reminding the user to connect the floor sensor (AF and F model only)
Comfort temperature mode
Economy temperature mode
Vacation temperature mode
Touch to view floor temperature for 5 seconds (AF model only)
Touch to start programming of your thermostat
Set
Schedule
Touch to switch among Auto
Heating
Mode
Set Menu
or
adjust the settings. Touch
( AF model only)
or
to change the time faster. Touch
to store and exit.
, each of these manual modes maintains a constant set temperature set by the user.
or
to adjust to the required temperature. Touch
Day 1= Monday, Day 2= Tuesday... etc.
Done
to accept and store.
Touch
or
A, AF, F
1 °C, 2 °C, ...10°C, 1°C by default
0 °C by default, -5°C ~ +5°C
0 °C by default, -5°C ~ +5°C
40 °C by default, setting range 20°C ~ 40°C
10, 20,30,40,50,60 seconds. 30 seconds by default
C / F
24H / 12H
24 hour clock by default
ON = activated; OFF = deactivated
5 2 = 5+2 day programmable
7 = 7 day programmable (by default)
ON = sound audible; OFF = sound off
For review only
to store and exit.
Done
to store and exit.
Done
Edited with the trial version of
Foxit Advanced PDF Editor
To remove this notice, visit:
www.foxitsoftware.com/shopping
to adjust