IPアクセスコントローラ ATT Holding Kade KZ-700-U/HのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。ATT Holding Kade KZ-700-U/H 12 ページ。 Integrated access controller

Integrated Access Controller – Installation manual
Change Zone 2 to Door Bell
(When no need to operate a second door, Zone 2 can be set to operate the Door Bell. The wiring is connect-
ing the door bell to COM2 and NO2. Press #, the keypad will send the signal to the door bell.
Zone 2
Door bell
To remove the alarm
To reset the Door Forced Open warning
To reset the Door Open Too Long warning
Duress User Settings
There are 10 groups Duress PIN/card available. When input Duress PIN/card, the door will open, at the
same time, the output alarm operates.
To set Duress PIN User
To add a PIN user
To delete a PIN user
To set Duress card user
To add a card user by read card
To add a card user by card number
To delete a card user
To delete All Duress users
Note that this is a dangerous option so
use with care
Note:
User ID number must be any 4digits between 2101 ~ 2110
Duress PIN/card must be unique, should be distinguished from common PIN/card
(When the Duress PIN/card is the same with common PIN/card, they will become invalid in Duress, and
worked as common user function)
Wiegand Mode Setting
KZ-700-U/H supports Wiegand 26~37, both input and output. It can be used as a reader or controller.
To Set Wiegand format:
All rights reserved. © AAT HOLDING S.A.
84 0 # Factory default.
84 1 #
Read valid card or Master Code #
Close the door or Read valid card or Master Code #
1 3 user ID number # PIN #
As the same method of deleting common PIN user
(The ID number is any number between 2101~2110.)
1 3 read card 1 # read card 2 ... #
(The ID number is any number between 2101~2010.)
1 3 user ID number # card ... #
(The ID number is any number between 2101~2010.)
As the same method of deleting common card user
2 3 0000 #
9 26~37 # (Default setting: Wiegand 26)
11