ウォーターヒーター ATTACK PZO 150のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。ATTACK PZO 150 12 ページ。 Direct heated gas tanks for d.h.w

NOTE
Water must be treated by the standard. In case of deviation, an equipment for water
treatment must be installed to the tank.
WARNING
The water storage tank cannot be put into operation in any case without the safety valve fitted
and it cannot be removed.
CONNECTION TO FLUE
The appliance must be connected to a waste gas exhaust with the diameter of 100 mm. Waste
gas must be removed using the flue breaker and non-return flap against backward flow of
waste gas.
Connecting waste gas exhaust to flue must be done by the demands of standards. The flue to
which the appliance is connected must be tested by a special company. If the gas boiler and
water storage tank share operation, they can be connected to one flue only under the
condition it is dimensioned sufficiently to the output of both the appliances.
Each water storage tank works without outside source of power and it is not possible to
connect it with a flue flap electrically controlled.
Although technically it is possible to fit a bimetal flue flap due to low total savings, because of
some negative guiding signs (first of all higher noisiness of operation) it is only rarely used.

OPERATION

WARNING!
Water storage tank can be put into operation only when filled by water!

PROCEDURE OF FILLING THE TANK WITH WATER:

- Open the valve on the inlet of cold water. The valve must be always open during the
operation of the tank.
- Deaerate the tank through water-pipe fittings.
- Check the tightness of the fitting.
CHECK BEFORE IGNITION
WARNING!
* Water storage tank can be put into operation only by a trained worker of one of the service
organizations the list of which is in the supplement.
* To keep the user safe, natural gas, otherwise without smell, is mixed with aromatic materials,
so called odourisation of gas. If you smell gas in a room, do not use open faire, electric
appliances (no telephone) and do not carry out any activity which might cause sparkling. The
room must be aired, gas valve closed and the failure announced to a gas company or to a
service technician.
6