3.2 – 3rd Party Usage
The Zip4 can also be used with other non-Q-SYS systems too.
The 3
party system will be required to
rd
1)
Send UDP messages to the ZIP4 to setup parameters and
update the status of the indicator LED's on the Zip4.
2)
Accept asynchronous UDP message indicating an event
such as a button press or release and acknowledge it by
sending a message back.
Complete information on the exact protocol can be found in the
customer portal section of the Attero Tech website (link here).
3.3 – Factory Reset
The Zip4 includes a factory reset function. Activating it affects
both Dante™ and non-Dante™ settings of the device. All Dante™
settings are reset including device name and channel names, the
Ethernet port mode will be defaulted back to redundant mode and
the IP address setup will be reset to get an IP address dynamically.
The factory reset switch is accessed through a small hole on next
to the vent holes on the bottom of the unit. To activate the factory
reset, insert a paperclip or small screw driver into the factory
reset hole and press and hold the factory switch for five seconds.
If the reset was successful, the unit should reboot.
3.4 – Firmware Updates
If a firmware update for the Zip4 is released, it may be applied in
the field by the end user or installer. The update process takes
advantage of the smart firmware update tool in Attero Tech's
unIFY Control Panel application. The latest version of unIFY
Control Panel application is available from the
website.
To apply the update, download the appropriate SFU file for the
Zip4, select the smart firmware update option under the "Tools"
menu and follow the instructions. Further assistance for
implementing updates is provided in the unIFY Control Panel
manual.