- ページ 8

安全装置 DSSA Combo 64のPDF マニュアルをオンラインで閲覧またはダウンロードできます。DSSA Combo 64 9 ページ。

1. Disconnect Battery before doing any connection.
2. Connect Ignition Switch to the Combo 64 Ignition Switch input respectively.
3. Connect Daytime Running Light to Combo 64 Daytime Running Light Output.
4. Ensure the polarity Ignition Switch, and set the DIP switch setting accordingly.
5. Connect the Battery to Combo 64.
6. Switch OFF BOTH Park Light/Ignition Switch, Daytime Running Light should turn OFF.
7. Switch ON Ignition Switch, Daytime Running Light should turn ON after 5 seconds.
8. Switch OFF Ignition Switch, Daytime Running Light should turn OFF after 20 Seconds.
9. Switch ON Ignition Switch again, Daytime Running Light should turn ON after 5 seconds.
10. Switch ON Park Light, Daytime Running Light should turn OFF immediately.
11. Switch OFF Park Light, Daytime Running Light should turn ON after 5 seconds.
Input Connector
Output Connector
Operating Temperature
Storage Temperature
Dimensions (mm)
Problem
No response from
Safe Guard 64
Combo 64
No output from
Safe Guard 64
Combo 64
Daytime Running
Light do not light
up
Daytime Running
Light take a long
time to switch off
D
S S
A
Digital witching ystems Australia
S
S
1. Check if the power is good
2. Check if the connections are good
3. Check if the DIP switch setting is correctly set
1. Check if the connections are good
2. Check if the LED display is correct
3. Check if the fuse is broken (indicated by RED LED next to the
1. Check if the connections are good
2. Check if the battery voltage is greater than the turn-on threshold
setting when the engine is running in case voltage setting is used
1. Change to use the Ignition Switch setting
For Ignition Setting

Mechanical Parameters

Phoenix Connector 1 x 6 Pin
Phoenix Connector 2 x 6 Pin
- 20 C to 85 C
- 40 C to 85 C
111.5(L) x 90.5(W) x 32(D)
Trouble Shooting
Check
relay)