ATTO Technology Celerity FC-82EN 仕様書
Celerity FC-82EN
Host Adapter
Hardware Specifications
Fibre Channel Interface
Advanced FC Capabilities
Host Bus Specifications
External Connectivity
Software Specifications
Driver Support
Agency Approvals
Safety and Environmental
Environmental & Physical Specifications
Dimensions
Operating Environment
Storage Environment
Power
Airflow
Optical Cabling
RoHS Compliant
Ordering Information
Model Number
Technical Specification
Celerity FC-82EN
©2008 ATTO Technology, Inc. Specifications subject to change without notice
Two independent FC ports
8-Gigabit FC data-transfer rates
1600 MB/sec. maximum full-duplex throughput per channel
Supports all FC topologies: fabric, arbitrated loop and point-to-point
ANSI Fibre Channel: FC-FS, FCP, FC-AL, FC-AL2, FC-PLDA, FC-FLA
Flash ROM for easy field upgrades
FC Class 3 Support
Local management and diagnostics
Buffer Credits: 41
TM
Advanced Data Streaming (ADS
Supports SNIA HBA API
Supports Windows FDMI and WMI
Supports Target and Initiator modes
Backward compatible with 4-Gb and 2-Gb Fibre Channel
x8 mechanical and x8 electrical PCI Express 2.0 interconnect
Supports PCI Express Base Spec 2.0
Supports PCI Express CEM Spec 2.0
PCI Hot Plug spec 1.0
Easy-to-install full height connection bracket; low-profile bracket included in Finished Goods packaging
External LEDs for on-line and speed status for each channel
Two (2) pluggable 8Gb optical LC SFP+ modules included
Windows Server 2003, 2008, XP, Vista
Red Hat Linux (2.6 kernel)
SUSE Linux (2.6 kernel)
Fedora Linux (7 & 8)
Mac OS X (10.4.x & 10.5.x)
FCC Part 15, Subpart B, Class B
EN55022: 2006, Class B
EN55024: 1998A + A1: 2001 & A2: 2003
EN60950-1: 2001
EN60825-1: 1994-2: 2004
Conforms to PCI Express Low Profile form-factor specifications
Length 6.600"
Height
2.731"
Temperature: 0-40° C
Humidity: 10 - 90% non-condensing
Temperature: -40°-70°C (-40°-157°F)
Humidity: 5 - 95% non-condensing
5.9W (Typical)
100 lf/m (min) recommended
50/125µm up to 50m @ 8-Gb
50/125µm up to 150m @ 4-Gb
50/125µm up to 300m @ 2-Gb
Yes
CTFC-82EN-000
Power Behind the Storage
) Technology
For More Information:
www.ATTOTech.com
or to Purchase:
www.ATTOStore.com
(716) 691-1999
Rev 09/08