Power should be disconnected from the power supply before connecting
it to the switch. Otherwise, your screwdriver blade can inadvertently short
your terminal connections to the grounded enclosure.
Wiring the Alarm Relay Output
The alarm relay output or digital output (DO) contacts are on the terminal
block connector on the bottom of the ES8508.
The relay contact supports up to 1A at 24VDC. Do not apply voltage and
current higher than the specifications.
The alarm relay output is
controlled by the pre-defined
operating rules. To activate the
alarm relay output function, refer
to the RocketLinx ES8508
Series User Guide .